Repositioning of Ahmed glaucoma valve tube in the anterior chamber with prolene sutures to manage tube-endothelial touch.
نویسندگان
چکیده
BACKGROUND Corneal endothelial damage is a known complication of aqueous shunt surgery. OBJECTIVE To describe a new technique for repositioning the Ahmed glaucoma valve tube in a case of tube-endothelial touch. CASE A patient with advanced glaucoma, having undergone Ahmed glaucoma valve (AVG) implantation, developed localized corneal endothelial damage due to contact between the tube and superior corneal endothelium. Two 10-0 prolene anchor sutures were passed over the tube in the anterior chamber, repositioning it away from the endothelium, thus preventing further damage to the corneal endothelium. Resolution of corneal oedema was noted without affecting the tube drainage and intraocular pressure. CONCLUSION Intracameral repositioning of the shunt tube using prolene sutures is a useful technique for correcting the tube malposition.
منابع مشابه
Scleral fistula closure at the time of glaucoma drainage device tube repositioning: a novel technique.
Repositioning a glaucoma drainage device tube from the anterior chamber to the ciliary sulcus or pars plana can be a challenging procedure owing to the difficulty in obtaining tight closure of the original limbal fistula. Failure to achieve watertight and airtight closure of the fistula can result in substantial difficulty in completing other key portions of the surgery and may lead to postoper...
متن کاملModification of silicone oil retention sutures in aphakic eyes with iris loss.
Silicone oil (SO) is a long-term intraocular tamponade used for a variety of retinal disorders. In aphakic eyes with an intact iris, the use of an inferior peripheral iridectomy prevents SO prolapse into the anterior chamber, thereby preventing glaucoma and keratopathy. We have developed a technique for preventing SO from entering the anterior chamber in aphakic eyes with iris loss. The techniq...
متن کاملIntraocular lens dislocation and tube shunt in the posterior chamber: a case report
BACKGROUND To describe management of a case of intraocular lens (IOL) and capsular bag (CB) dislocation in an eye with an Ahmed glaucoma valve in the posterior chamber. CASE PRESENTATION A 75-year-old pseudophakic man with open-angle glaucoma and diabetic retinopathy developed neovascular glaucoma. After two intravitreous injections of bevacizumab and panretinal photocoagulation were administ...
متن کاملA case involving an Ahmed™ glaucoma valve transferred from the vitreous into the anterior chamber of the eye with a silicone oil tamponade for the treatment of neovascular glaucoma
PURPOSE To report the short-term efficacy and safety of the transfer of an Ahmed(™) glaucoma valve (AGV™) tube from the vitreous into the anterior chamber, in a patient with neovascular glaucoma who had undergone pars plana AGV(™) implantation and ultimately needed a silicone oil tamponade. CASE A 41-year-old male with proliferative diabetic retinopathy in both eyes was referred to us for tre...
متن کاملEYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma
Aims—To evaluate the eYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucomas. Methods—This retrospective study reviewed the final intraocular pressure, visual outcome, and incidence of complications in all patients with the Ahmed glaucoma valve implant performed at the Prince of Wales Hospital, Hong Kong, between June 1996 and November 1998. Results—A to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nepalese journal of ophthalmology : a biannual peer-reviewed academic journal of the Nepal Ophthalmic Society : NEPJOPH
دوره 4 2 شماره
صفحات -
تاریخ انتشار 2012