Making post-mortem implantable cardioverter defibrillator explantation safe
نویسندگان
چکیده
AIMS The aim of this study is to investigate whether protection with rubber or plastic gloves during post-mortem explantation of an implantable cardioverter defibrillator (ICD) offers enough protection for the explanting operator during a worst-case scenario (i.e. ICD shock). METHODS AND RESULTS We investigated the insulating properties of rubber and plastic gloves (double layer) within the first 60 min exposure (mimicking the maximum time of an explantation procedure) to saline (simulating the effects of body fluids on the gloves). For latex gloves, we measured an increase in voltage up to 68.1 V (P < 0.0001), for neoprene a maximum voltage of 5.3 V (P = 0.245), and for plastic a voltage of 2.3 V within the first hour. If the exposure time to fluid did not exceed 50 min, a double pair of intact gloves made of latex, neoprene, or plastic constituted such a large resistance that the resting voltage over the operating person would not exceed 50 V. CONCLUSION The use of intact medical gloves made of latex, neoprene, or plastic eliminates the potential electrical risk during explantation of an ICD. Two gloves on each hand offer sufficient protection. We will recommend the use of neoprene gloves.
منابع مشابه
THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کامل"Natural death" of a patient with a deactivated implantable-cardioverter-defibrillator (ICD)?
A 66-year-old patient with terminal heart insufficiency (NYHA IV) received maximum medical therapy, but was also in need of an implantable-cardioverter-defibrillator (ICD). The ICD functioned flawlessly for the whole duration of implantation. It reverted several ventricular tachycardias with anti-tachycardial pacing alone, whereas some needed cardioversion as well. The patient died on the fourt...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملExperience With the WCD
RESULTS: Ninety-four patients (1.6%) were treated by the WCD in response to ventricular tachyarrhythmia/fibrillation. The incidence rate was 8.4 (95% confidence interval, 6.8–10.2) per 100 patient-years. Patients with implantable cardioverter-defibrillator explantation had an incidence rate of 19.3 (95% confidence interval, 12.2–29.0) per 100 patient-years. In contrast, an incidence rate of 8.2...
متن کاملThe effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)
Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...
متن کامل