Tracheal intubation using the GlideScope with a combined curved pipe stylet, and endotracheal tube introducer.

نویسندگان

  • Musa Muallem
  • Anis Baraka
چکیده

CAN J ANESTH 54: 1 www.cja-jca.org January, 2007 8 Hernandez-Diaz S, Varas-Lorenzo C, Garcia Rodriguez LA. Non-steroidal antiinflammatory drugs and the risk of acute myocardial infarction. Basic Clin Pharmacol Toxicol 2006; 98: 266–74. 9 Kearney PM, Baigent C, Godwin J, Halls H, Emberson JR, Patrono C. Do selective cyclo-oxygenase-2 inhibitors and traditional non-steroidal anti-inflammatory drugs increase the risk of atherothrombosis? Metaanalysis of randomised trials. BMJ 2006; 332: 1302–8.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aids for facilitation of difficult tracheal intubation review and recent advances.

Management of difficult tracheal intubation has been facilitated by different techniques which include the use of stylets, introducers, intubating laryngeal mask airway, as well as by the development of special laryngoscope blades and fiberoptic laryngoscopes. The most recent advances for facilitation of difficult tracheal intubation is the introduction of the video-assisted laryngoscopes. The ...

متن کامل

Methods to Improve Success With the GlideScope Video Laryngoscope.

Occasionally intubation of patients is difficult using a video laryngoscope (GlideScope, Verathon Medical) because of an inability to guide the endotracheal tube to the glottis or pass the tube into the trachea despite an adequate view of the glottis. We examined methods to improve success when this difficulty occurs. A literature search revealed 253 potential sources, with 25 meeting search cr...

متن کامل

GlideScope and Frova Introducer for Difficult Airway Management

The introduction into clinical practice of new tools for intubation as videolaringoscopia has dramatically improved the success rate of intubation and the work of anesthesiologists in what is considered the most delicate maneuver. Nevertheless intubation difficulties may also be encountered with good anatomical visualization of glottic structures in videolaringoscopia. To overcome the obstacles...

متن کامل

Improving patient safety by design -- a new spinal/intrathecal injection safety system.

readily be achieved with the inverted insertion (i.e., with the concave surface facing backward) of a polyvinyl chloride endotracheal tube.2 They attributed their success, in part, to the more anatomic direction of the tube on emergence from the Fastrach laryngeal mask airway with the inverted tube insertion technique. A similar “hang up” is often seen during tracheal intubation using the Bulla...

متن کامل

Penetrating injury of the soft palate by a microlaryngeal tracheal tube during GlideScope® intubation

Dear Editor, A 57-year-old man presented for suspension microlaryngoscopy and biopsy of a laryngeal lesion that was mildly obstructive. After induction of general anaesthesia, a standard midline approach of glideScope laryngoscopy provided good laryngeal exposure. A junior anaesthesiologist made a failed attempt to introduce a 5.0-mm internal diameter cuffed microlaryngeal tracheal (MlT) tube w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 54 1  شماره 

صفحات  -

تاریخ انتشار 2007