Influence of contractile force on properties of motor unit action potentials: ADEMG analysis.
نویسندگان
چکیده
We have used automatic decomposition electromyography (ADEMG) to measure the configurational and firing properties of 13,206 motor unit action potentials (MUAPs) in the brachial biceps, brachial triceps and anterior tibial muscles of 30 healthy adults (22 men, 8 women; mean age 48.6 +/- 16.9 years, range 20-76) at three levels of isometric contractile force: threshold, 10% of maximum voluntary contraction (MVC), and 30% MVC. In all muscles, the increment in contractile force from threshold to 10% MVC was associated with a significant (P less than 0.05, paired t-test) increase in mean MUAP firing rate and number of turns per MUAP. The increment from 10% to 30% MVC led to highly significant (P less than 0.005) increase in mean firing rate, number of turns, amplitude and rise rate. Each force increment was associated with an increase in the number of simultaneously-active MUAPs per recording site; and with a significant decrease in mean MUAP duration in all muscles, due to noise-dependency of the duration measurement. Quantitatively, the changes in MUAP properties with force were comparable to or exceeded the effects of age, gender differences, or intermuscular variability. Test-retest measurements 2 years apart in a subgroup of young adults showed good correspondence of mean MUAP properties with force standardization. These results demonstrate that contractile force is a major determinant of MUAP shape and behavior properties, and so must be precisely measured or controlled in clinical EMG studies.
منابع مشابه
Motor unit recruitment strategies and muscle properties determine the influence of synaptic noise on force steadiness.
Motoneurons receive synaptic inputs from tens of thousands of connections that cause membrane potential to fluctuate continuously (synaptic noise), which introduces variability in discharge times of action potentials. We hypothesized that the influence of synaptic noise on force steadiness during voluntary contractions is limited to low muscle forces. The hypothesis was examined with an analyti...
متن کاملCorrection: Limitations of the Spike-Triggered Averaging for Estimating Motor Unit Twitch Force: A Theoretical Analysis
Contractile properties of human motor units provide information on the force capacity and fatigability of muscles. The spike-triggered averaging technique (STA) is a conventional method used to estimate the twitch waveform of single motor units in vivo by averaging the joint force signal. Several limitations of this technique have been previously discussed in an empirical way, using simulated a...
متن کاملRelationship between electrical and mechanical properties of motor units.
In six healthy volunteers, the size of the motor unit action potential (MUAP) was related to its contractile behaviour. Electrical activity was determined by measuring amplitude and area of the potential, using the macro electromyography (EMG) technique. The mechanical response was characterised by contraction time, twitch force and relaxation time, recorded with the spike triggered averaging t...
متن کاملThe aging neuromuscular system and motor performance.
Age-related changes in the basic functional unit of the neuromuscular system, the motor unit, and its neural inputs have a profound effect on motor function, especially among the expanding number of old (older than ∼60 yr) and very old (older than ∼80 yr) adults. This review presents evidence that age-related changes in motor unit morphology and properties lead to impaired motor performance tha...
متن کاملA Hybrid Classifier for Characterizing Motor Unit Action Potentials in Diagnosing Neuromuscular Disorders
Background: The time and frequency features of motor unit action potentials (MUAPs) extracted from electromyographic (EMG) signal provide discriminative information for diagnosis and treatment of neuromuscular disorders. However, the results of conventional automatic diagnosis methods using MUAP features is not convincing yet.Objective: The main goal in designing a MUAP characterization system ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the neurological sciences
دوره 86 2-3 شماره
صفحات -
تاریخ انتشار 1988