Haemodynamic effects of hyperbaric hyperoxia in healthy volunteers: an echocardiographic and Doppler study.

نویسندگان

  • Florence Molénat
  • Alain Boussuges
  • Aliocha Grandfond
  • Jean-Claude Rostain
  • Jean-Marie Sainty
  • Claude Robinet
  • François Galland
  • Jean Louis Meliet
چکیده

In the present study, we observed the haemodynamic changes, using echocardiography and Doppler, in ten healthy volunteers during 6 h of compression in a hyperbaric chamber with a protocol designed to reproduce the conditions as near as possible to a real dive. Ambient pressure varied from 1.6 to 3 atm (1 atm=101.325 kPa) and partial pressure of inspired O2 from 1.2 to 2.8 atm. Subjects performed periods of exercise with breathing through a closed-circuit self-contained underwater breathing apparatus (SCUBA). Subjects did not eat or drink during the study. Examinations were performed after 15 min and 5 h. After 15 min, stroke volume (SV), left atrial (LA) diameter and left ventricular (LV) end-diastolic diameter (LVEDD) decreased. Heart rate (HR) and cardiac output (CO) did not vary, but indices of the LV systolic performance decreased by 10% and the LV meridional wall stress increased by 17%. After 5 h, although weight decreased, the serum protein concentration increased. Compared with values obtained after 15 min, SV and CO decreased, but LV systolic performance, LA diameter, LVEDD and LV meridional wall stress remained unchanged. Compared with the reference values obtained at sea level, total arterial compliance decreased, HR remained unchanged and CO decreased. In conclusion, hyperbaric hyperoxia results in significant haemodynamic changes. Initially, hyperoxia and the SCUBA system are responsible for reducing LV preload, increasing LV afterload and decreasing LV systolic performance, although CO did not change. Prolonged exposure resulted in a further decrease in LV preload, because of dehydration, and in a further increase in LV afterload, due to systemic vasoconstriction, with the consequence of decreasing CO.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study Of Interaction of Glutathione, Vitamin C and Vitamin E Under Hyperbaric Oxygen

In order to study the interaction of glutathione, vitamin C and vitamin E under hyperoxia (95 % oxygen) and hyperbaric oxygen (2.5 atmospheric pressure), 20 days old male Guinea pigs were fed with basal vitamin C free diet, while receiving a vitamin C supplement of either high concentration (50 mg/day) or low concentration (1 mg/day) for two weeks. Animals were than exposed to hyperoxia and hyp...

متن کامل

Echocardiographic Assessment of Left Ventricle Torsion by Tissue Doppler and Velocity Vector Imaging

Introduction Left ventricular (LV) twist is believed to store potential energy and plays an important role in generating diastolic suction. Recent advances in echocardiography techniques have allowed quantification of LV twist. The aim of the present study was to compare LV twist and torsion in healthy human subjects determined by velocity vector imaging (VVI) and tissue Doppler imaging (TDI) a...

متن کامل

Lipopolysaccharide infusion enhances dynamic cerebral autoregulation without affecting cerebral oxygen vasoreactivity in healthy volunteers

INTRODUCTION Sepsis may be associated with disturbances in cerebral oxygen transport and cerebral haemodynamic function, thus rendering the brain particularly susceptible to hypoxia. The purpose of this study was to assess the impact of isocapnic hypoxia and hyperoxia on dynamic cerebral autoregulation in a human-experimental model of the systemic inflammatory response during the early stages o...

متن کامل

Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...

متن کامل

Lack of toxic side effects in neutrophils following hyperbaric oxygen.

Conflicting data have been reported about the impact of repeated HBO2 exposure on the production of superoxide radicals during the neutrophil respiratory burst (RB) and on phagocytosis. In this study we wanted to see if exposure to hyperoxia would affect human neutrophil RB and phagocytosis. Short- and long-term effects after single or repetitive HBO2 exposure of 2.5 atmospheres absolute over a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science

دوره 106 4  شماره 

صفحات  -

تاریخ انتشار 2004