Efficacy and safety of early comprehensive cardiac rehabilitation following the implantation of cardioverter-defibrillator.

نویسندگان

  • Jacek Śmiałek
  • Jacek Lelakowski
  • Jacek Majewski
چکیده

BACKGROUND Implantable cardioverter-defibrillator (ICD) therapy is current the main approach to prevent sudden cardiac death. It was demonstrated that patients with ICD are characterised by worse quality of life (QOL) and exercise capacity and are prone to depressive symptoms. Thus, comprehensive rehabilitation is indicated in ICD recipients. AIM To evaluate safety and benefits of comprehensive cardiac rehabilitation early after ICD implantation. METHODS The study group consisted of 45 patients (28 males, mean age 62.2 years) in whom a program of comprehensive cardiac rehabilitation was initiated at 6 weeks after ICD implantation. Rehabilitation consisted of two phases: 2-week inpatient Phase I and 12-week outpatient Phase II. Before and after the rehabilitation program, all patients were evaluated with transthoracic echocardiography, treadmill spiroergometric exercise test according to the modified Naughton protocol, a Polish version of the SF-36 questionnaire to assess QOL, and the Beck Depression Inventory (BDI) for depressive symptoms. RESULTS No deaths during the study and no complications or adverse events during rehabilitation or exercise testing were noted. Following comprehensive cardiac rehabilitation, we found an increase in left ventricular ejection fraction (30.09 ± 12.75 vs. 35.43 ± 13.4%; p = 0.002), peak oxygen uptake (VO₂) (21.3 ± 9.2 vs. 24.2 ± 10.3 mL/kg/min; p = 0.007) and duration of exercise (9.14 ± 3.7 vs. 9.53 ± 3.8 min; p < 0.05). An improvement was also noted in terms of depressive symptoms, as BDI score decreased (14.81 ± 9.27 vs. 12.83 ± 10.75; p = 0.020). QOL improved (p < 0.05), particularly the physical index (p = 0.02), as was the New York Heart Association class (p < 0.001). Improvement in peak VO₂ was associated with better QOL (SF-total, r = -0.34; and physical index, r = -0.36). We also found a correlation between alleviation of depressive symptoms (BDI score) and improvement of QOL (SF-total, r = 0.52). CONCLUSIONS An improvement in left ventricular systolic function, exercise capacity and QOL and a reduction of depressive symptoms were observed in patients who took part in a program of early comprehensive cardiac rehabilitation after ICD implantation. No complications or side effects during rehabilitation sessions or exercise tests were observed in the study group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes: Findings from the COPE-ICD randomized controlled trial.

OBJECTIVE The Copenhagen Outpatient ProgrammE - implantable cardioverter defibrillator (COPE-ICD) trial included patients with implantable cardioverter defibrillators in a randomized controlled trial of rehabilitation. After 6-12 months significant differences were found in favour of the rehabilitation group for exercise capacity, general and mental health. The aim of this paper is to explore t...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 71 10  شماره 

صفحات  -

تاریخ انتشار 2013