Self-Calibration of a Lecia HDS7000 Scanner
نویسنده
چکیده
SUMMARY Terrestrial laser scanners are widely used for metric applications of 3D modelling of buildings, bridges, tunnels and other structures. In common with any measurement system, the calibration of the laser scanner is of paramount importance to achieve the maximum possible accuracy. Even if a calibration certificate of the scanner is provided by the vendor, the scanner should be checked from time to time for any systematic errors using special equipment and facilitates. This process is time consuming as the scanner needs to be sent to vendor for long time. The self-calibration method provides a very flexible yet rigorous solution that allows scanner users to calibrate instruments themselves. This paper uses the self-calibration approach to develop and establish a calibration model for Leica HDS7000 phase-based terrestrial laser scanner. The calibration process and a calibration field of signalised targets designed to perform the calibration are described. The final results show the importance and potential of the self-calibration method, especially when high-precision measurements are required. Two highly-redundant (nearly 5000 degrees-of-freedom) calibrations of the scanner were conducted on separate dates. Statistically significant angular errors (collimation axis, trunnion axis; vertical axis-horizontal encoder non-orthogonality and vertical circle index) were found in both datasets. A small (0.6 mm), but statistically significant, rangefinder offset parameter was also estimated. The improvements gained as a result of the modelling were 41% and 45% in the horizontal angle direction residuals and 54% and 87% in the elevation angle residuals for the first and second datasets, respectively.
منابع مشابه
Colorimetric Scanner Calibration for Textiles by Neural-Network
In this study, colorimetric calibration of scanner has been done via perceptron neural network with three or four layers by back propagation algorithm for colored polyester fabrics. The results obtained for random training samples are not satisfactory but application of selective training samples for L*a*b* or RGB leads to good results, with better results obtained for the L*a*b* method. On the...
متن کاملColorimetric Scanner Calibration for Textiles by Neural-Network
In this study, colorimetric calibration of scanner has been done via perceptron neural network with three or four layers by back propagation algorithm for colored polyester fabrics. The results obtained for random training samples are not satisfactory but application of selective training samples for L*a*b* or RGB leads to good results, with better results obtained for the L*a*b* method. On the...
متن کاملPoint-based versus Plane-based Self-calibration of Static Terrestrial Laser Scanners
Systematic trends are apparent when studying the self-calibration residuals of many modern static terrestrial laser scanners. Since the operation of terrestrial laser scanners is comparable to an efficient robotic total station, the sensor modelling parameters are developed in the spherical coordinate system where the raw observables of the scanner are range, horizontal angle, and vertical angl...
متن کاملSelf-calibration and Evaluation of the Trimble Gx Terrestrial Laser Scanner
There are numerous imaging modalities for reconstructing 3D object space on the market. Among all the varieties, which include 3D TOF range cameras, structured light systems, and traditional photogrammetric systems, terrestrial laser scanners have gained the most attention and demand from the surveying and engineering discipline. This is probably because of the large field of view and rapid den...
متن کاملTowards System Calibration of Panoramic Laser Scanners from a Single Station
Terrestrial laser scanner measurements suffer from systematic errors due to internal misalignments. The magnitude of the resulting errors in the point cloud in many cases exceeds the magnitude of random errors. Hence, the task of calibrating a laser scanner is important for applications with high accuracy demands. This paper primarily addresses the case of panoramic terrestrial laser scanners. ...
متن کامل