The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer1
نویسندگان
چکیده
High-intensity focused ultrasound (HIFU) is a rapidly developing, non-invasive technique for local treatment of solid tumors that produce coagulative tumor necrosis. This study is aimed to investigate the feasibility of proton magnetic resonance spectroscopy (MRS) on early assessing treatment of HIFU ablation in rabbit with VX2 liver tumor. HIFU ablation was performed on normal liver and VX2 tumor in rabbit, and MRS was performed on normal liver and VX2 tumor before and 2 days after 100% HIFU ablation or 80% ablation in tumor volume. Choline (Cho) and choline/lipid (Cho/Lip) ratios between complete and partial HIFU ablation of tumor were compared. Tissues were harvested and sequentially sliced to confirm the necrosis. In normal liver, the Cho value liver was not obviously changed after HIFU (P N .05), but the Cho/Lip ratio was decreased (P b .05). Cho in liver VX2 tumor was much higher than that in normal liver (P b .001). Cho and Cho/Lip ratio were significantly decreased in tumor after complete HIFU ablation and partial HIFU ablation, and the Cho value in complete HIFU tumor ablation did not show any difference from that in normal liver after HIFU (P N .05); however, the Cho value in partial ablation was still higher than that in normal liver before or in tumor after complete HIFU treatment due to the residual part of tumors, and Cho/Lip ratio is lower than that in complete HIFU treatment (P b .001). The changes in MRS parameters were consistent with histopathologic changes of the tumor tissues after treatment. MRS could differentiate the complete tumor necrosis from residual tumor tissue, when combined with magnetic resonance imaging. We conclude that MRS may be applied as an important, non-invasive biomarker for monitoring the thoroughness of
منابع مشابه
Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملFRI 7 In-vitro evaluation of thermal dose accuracy for high intensity focused ultrasound hyperthermia therapy: MRgFUS experience
High intensity focused ultrasound (HIFU) has performed its non-invasive heating capability for tumour treatment. Magnetic resonance image (MRI) guided HIFU surgery has been initially proved for uterine fibroid. ExAblate MRgFUS system (Insightec, Israel) recently demonstrated hyperthermia application for malignant bone metastasis palliation and been certificated by US FDA. HIFU beam projects ult...
متن کاملAssessment of Cerebellar Metabolites Levels in Athletes Compared to Non-Athlete by Proton Magnetic Resonance Spectroscopy
Background: Adaptability to exercise training can increase the plasticity of the brain, and whether this can be due to a beneficial change in the neurometabolites, is uncertain. The purpose of this study was to evaluate basal metabolic concentrations of cerebellum, including N-acetyl aspartate (NAA) and Cholin(Cho) in athletes and compare them with non-athlete subjects. Materials and Methods: I...
متن کاملTherapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics
Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...
متن کاملThe safety and effectiveness of volumetric magnetic resonance-guided high-intensity focused ultrasound treatment of symptomatic uterine fibroids: early clinical experience in China
BACKGROUND Uterine fibroids are the most common benign tumor in women, and surgical intervention is still the main fibroid treatment. Patient demands have encouraged development of less-invasive methods such as high-intensity focused ultrasound (HIFU). This study aimed to evaluate the safety and effectiveness of magnetic resonance-guided high-intensity focused ultrasound therapy using a volumet...
متن کامل