Chemically determined mineral content of explanted porcine aortic valve bioprostheses: correlation with radiographic assessment of calcification and clinical data.

نویسندگان

  • F J Schoen
  • J L Kujovich
  • C L Webb
  • R J Levy
چکیده

Bioprosthetic valve calcification is usually assessed pathologically by gross inspection, radiographic studies, and histologic examination. Quantitation of mineral content by chemical assay has not been reported for failed clinical valves removed from adults. In this study, calcium determination by atomic absorption spectroscopy was done on 52 removed porcine valves after routine pathologic examination, including specimen radiography done by a standard technique. Specimens included 31 valves with calcific primary tissue failure, two calcified (but not overtly dysfunctional) valves removed simultaneously with failed valves, 14 nondeteriorated valves obtained at reoperation or autopsy after long-term implantation, and five valves removed within 1 month after insertion. Chemically determined mineral content varied widely among patients and duration of function. Valves with calcific failure had 113 +/- 68 micrograms/mg calcium overall (mean +/- SD) after 36 to 156 months (mean 87) of function. Almost all dysfunctional porcine valves with radiographically demonstrated calcific deposits had greater than 34 and 67 micrograms/mg calcium for mitral and aortic valves, respectively. Nondeteriorated valves (implanted 8 to 145 months, mean 57) had 5 +/- 6 micrograms/mg calcium. Failed aortic valves had more calcium than failed mitral valves and valves with calcific stenosis more than valves with regurgitation caused by calcification with tearing. Correlation of semiquantitative radiographic grading with chemically determined valve mineral was good, indicating that radiographic assessment of calcification may be used reliably for clinical comparisons between valves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DIAGNOSTIC METHODS VALVE REPLACEMENT Chemically determined mineral content of explanted porcine aortic valve bioprostheses: correlation with radiographic assessment of calcification and clinical data

Bioprosthetic valve calcification is usually assessed pathologically by gross inspection, radiographic studies, and histologic examination. Quantitation of mineral content by chemical assay has not been reported for failed clinical valves removed from adults. In this study, calcium determination by atomic absorption spectroscopy was done on 52 removed porcine valves after routine pathologic exa...

متن کامل

Kangaroo versus freestyle stentless bioprostheses in a juvenile sheep model: hemodynamic performance and calcification behavior.

BACKGROUND Glutaraldehyde-preserved bioprosthetic heart valve substitutes have limited performance and longevity due to tissue degeneration and calcification. The Freestyle valve (Medtronic Heart Valves, Inc, Minneapolis, MN) combines zero fixation pressure and proportional, variant-amino oleic acid (AOA) as antidegeneration and antimineralization measures. The aim of this study was to compare ...

متن کامل

Mechanism of efficacy of 2-amino oleic acid for inhibition of calcification of glutaraldehyde-pretreated porcine bioprosthetic heart valves.

BACKGROUND Calcification is a frequent cause of the clinical failures of glutaraldehyde-pretreated bioprosthetic heart valves (BPHV) fabricated from glutaraldehyde-cross-linked porcine aortic valves. 2-Amino oleic acid (AOA) has been shown in previous in vivo studies to be a promising anticalcification agent. Our objective was to investigate the mechanism of calcification inhibition mediated by...

متن کامل

Calcification of porcine prosthetic heart valves: a radiographic and light microscopy study.

To determine the incidence and extent of calcification of implanted glutaraldehyde-treated porcine prosthetic heart valves, 82 valves explanted from 73 patients were examined for calcium by radiography and light microscopy. At the time of valve implantation, the patients were 2 1/4-76 years old. The included 15 children (patients younger than 15 years of age, mean age at time of valve implantat...

متن کامل

Introduction of a flexible polymeric heart valve prosthesis with special design for mitral position.

BACKGROUND Current heart valve prostheses are constructed mimicking the native aortic valve. Special hemodynamic characteristics of the mitral valve such as a nonaxial central inflow with creation of a left ventricular vortex have so far not been taken into account. A new polycarbonaturethane (PCU) bileaflet heart valve prosthesis with special design for the mitral position is introduced, and r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 76 5  شماره 

صفحات  -

تاریخ انتشار 1987