Bacterial contamination of unused, disposable non-sterile gloves on a hospital orthopaedic ward.
نویسندگان
چکیده
BACKGROUND Non-sterile disposable gloves are used on large hospital wards, however their potential role as a vehicle for pathogen transmission has not been explored in this setting. AIMS This study investigates glove use on a hospital orthopaedic ward to examine whether pathogen contamination occurs prior to contact with patients. METHOD Glove samples were aseptically removed from boxes on a hospital orthopaedic ward on opening and days 3, 6 and 9 thereafter. Following elution of bacteria and viable counts, glove isolates were identified by standard techniques and 16s rDNA sequencing. Methicillin resistance of staphylococci was determined by disc diffusion, Epsilon tests and PCR. Gloves were inoculated to determine two isolate survival rates. RESULTS Total bacterial counts ranged from 0 to 9.6 x 10(3) cfu/glove. Environmental bacteria, particularly Bacillus species, were present on 31/38 (81.6%) of samples. Half (19/38) the samples were contaminated with skin commensals; coagulase negative staphylococci were predominant. Enterococcus faecalis , Klebsiella pneumoniae , Pseudomonas sp. or methicillin susceptible Staphylococcus aureus were recovered from 5/38 (13.2%) of samples. Significantly more skin commensals and pathogens were recovered from samples from days 3, 6, 9 than box-opening samples. Staphylococcus epidermidis and Klebsiella pneumoniae inoculated onto gloves remained viable for several days but counts decreased. CONCLUSION Health care workers introduced skin commensals and pathogenic bacteria into glove boxes indicating that unused, non-sterile gloves are potential pathogen transmission vehicles in hospitals. Findings highlight adherence to handwashing guidelines, common glove retrieval practice, and glove-box design as targets for decreasing bacteria transmission via gloves on hospital wards.
منابع مشابه
Can the design of glove dispensing boxes influence glove contamination?
BACKGROUND Few studies have explored the microbial contamination of glove boxes in clinical settings. The objective of this observational study was to investigate whether a new glove packaging system in which single gloves are dispensed vertically, cuff end first, has lower levels of contamination on the gloves and on the surface around the box aperture compared with conventional glove boxes. ...
متن کاملOccupational exposure to cytotoxic drugs in two UK oncology wards.
AIMS To investigate the potential exposure to cytotoxic drugs of staff on two oncology wards in a large district, UK hospital under normal working conditions. METHODS Cytotoxic drug exposure was monitored in urine samples, surface wipes, and on disposable gloves by using a number of commonly used marker drugs, namely cyclophosphamide, ifosfamide, methotrexate, and the platino coordinated drug...
متن کاملBacterial contamination of nonsterile disposable gloves before use.
BACKGROUND After Bacillus cereus recovery in opened boxes of disposable gloves, the bacteriological contamination of disposable nonsterile gloves kept stored in native packages was investigated prospectively. METHODS Thirty-six commercially available nonsterile nonpowdered disposable gloves made of latex, vinyl, or nitrile were cultured. RESULTS A large variety of spore-forming and non-spor...
متن کاملReducing bacterial contamination of enteral feeds.
OBJECTIVE It has previously been shown that microbial contamination of enteral feeds given to children in hospital and at home is common. This study therefore examined the effects of improvements in the enteral feeding protocol, coupled with an intensive staff training programme, on bacterial contamination. METHODS The enteral feeding protocol was modified by: priming the feeding set on an al...
متن کاملContaminação Microbiana Das Luvas De Procedimento Após a Abertura Da Caixa E Durante Sua Exposição Ambiental Contaminación Microbiana De Guantes De Procedimiento Luego De La Abertura De La Caja Y Durante Exposición Ambiental
The objective of this study was to quantify the colony forming units (cfu) on latex procedure gloves in the beginning, middle, and end of the containers in real (professional) and controlled (researcher) gloving situations; evaluate the microbial load of the gloves, considering the time of exposure in the environment. This comparative prospective study was conducted at an intensive care unit of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Australasian medical journal
دوره 6 6 شماره
صفحات -
تاریخ انتشار 2013