The influence of a diastasis screw on the outcome of Weber type-C ankle fractures.

نویسندگان

  • H R Chissell
  • J Jones
چکیده

We performed a retrospective study of the factors affecting the outcome of Weber type-C ankle fractures in 43 patients reviewed at two to nine years after injury. We determined the functional result in relation to the use of a diastasis screw, the accuracy of reduction, the presence of tibiotalar dislocation, and of injury to the medial side of the ankle by medial malleolar fracture or deltoid ligament rupture. We assessed the use of a diastasis screw as appropriate or inappropriate on the basis of an anatomical study performed by Boden et al (1989). The diastasis screw was used unnecessarily in 19 of the 31 patients so treated, but this did not appear to affect the final functional result. The worse functional results were in ankles dislocated at the initial injury, and in those with medial malleolar fractures as opposed to those with deltoid ligament ruptures. The best results were after accurate reduction of the fibula and the syndesmosis, and greater increase in the width of the syndesmosis was associated with a worse result. Our results suggest that an increase of more than 1.5 mm in syndesmosis width is unacceptable. We recommend that when the deltoid ligament is ruptured, a diastasis screw should be used if the fibular fracture is more than 3.5 cm above the top of the syndesmosis. When a medial malleolar fracture has been rigidly repaired a diastasis screw is required if the fibular fracture is more than 15 cm above the syndesmosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Weber C ankle fractures with tibiofibular diastasis: syndesmosis-only fixation

OBJECTIVES To evaluate syndesmosis-only fixation in Weber C ankle fractures with tibiofibular diastasis and to assess the need for additional fibular fixation. METHODS Twenty-one patients with Weber C ankle fractures and tibiofibular diastasis were followed for at least 24 months after treatment. In treatment of the Weber C fractures, only a syndesmosis screw was used through a mini open late...

متن کامل

Complications of syndesmotic screw removal.

BACKGROUND Currently, the metallic syndesmotic screw is the gold standard in the treatment of syndesmotic disruption. Whether or not this screw needs to be removed remains debatable. The aim of the current study was to determine the complications which occur following routine removal of the syndesmotic screw following operative treatment of unstable ankle fractures. METHODS This was a retrosp...

متن کامل

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...

متن کامل

Outcome after fixation of ankle fractures with an injury to the syndesmosis: the effect of the syndesmosis screw.

The purpose of this study was to compare the clinical and radiological outcome of patients with intact, broken and removed syndesmosis screws after Weber B or C ankle fracture with an associated injury to the syndesmosis. We hypothesised that there would be no difference. Of a possible 142 patients who fulfilled our inclusion criteria, 52 returned for clinical and radiological assessment at lea...

متن کامل

Internal Compression Screw Exchange for Reduction of Distal Tibiofibular Syndesmotic Injuries.

Traumatic injuries to the distal tibiofibular syndesmosis often accompany ankle fractures. Repair of the syndesmosis is critical for the normal function of the ankle joint. Conventional reduction of the diastasis is achieved with the use of a periarticular reduction clamp. The authors describe an alternative method for reduction of the syndesmosis using a screw exchange technique. This proposed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 77 3  شماره 

صفحات  -

تاریخ انتشار 1995