Three-dimensional morphometry of the proximal ulna: a comparison to currently used anatomically preshaped ulna plates.
نویسندگان
چکیده
BACKGROUND Anatomically preshaped plates are increasingly used for stabilization of comminuted olecranon and Monteggia fractures. The purposes of this study were to investigate the morphology of the proximal ulna and to compare morphologic findings with geometry of 4 preshaped ulna plates. MATERIALS AND METHODS Forty human elbows (mean age, 68 years; range, 21-98 years) were measured by 2 independent observers using 64-slice computed tomography scans and 3-dimensional measuring software. RESULTS Measurements showed a mean dorsal hook angle of 95.3° ± 9.0° (range, 74.7°-110.8°) with gender-specific differences (mean, 92.2° ± 8.1° in men and 98.3° ± 8.9° in women; P = .029); a mean distance from the tip of the olecranon to the proximal edge of the ulna of 24.7 ± 2.7 mm (range, 20-30.5 mm) with gender-specific differences (P = .00068); a mean varus angulation of 14.3° ± 3.6° (range, 5.8°-21.2°); and a mean anterior angulation (proximal ulna dorsal angulation) of 6.2° ± 2.7° (range, 1.0°-11.2°). The investigated plates offered a tolerable (± standard deviation) hook angle in 25% to 68%, an appropriate varus angulation in 0% to 20%, and an adequate anterior angulation in 23% to 88%. The intraclass correlation coefficient was between 0.74 and 0.91. CONCLUSION The proximal ulna has a gender-specific and variable morphology. Some currently used anatomically preshaped proximal ulna plates differ significantly from these morphologic findings. In cases where reduction is not exactly possible, application of an "anatomically preshaped" plate may result in poor reduction. Especially in case of Monteggia fractures with instability of the radiocapitellar joint, surgeons could be misguided by plates that do not incorporate anterior angulation, resulting in subluxation of the radial head on the capitellum.
منابع مشابه
Management of fractures of the proximal ulna.
Proximal ulna fractures can be difficult to manage because of the elbow's complex anatomy. Advances in understanding elbow anatomy and biomechanics, however, have led to new insights. Careful preoperative evaluation is critical because failure to restore normal anatomy of the proximal ulna could have a detrimental effect on postoperative elbow function. Management options include anatomic plate...
متن کاملAn assessment of proximal ulna dorsal angulation using digital radiographic images
Background: The architecture of adult ulna is unique among long bones that have been described in the literature. But the best of our knowledge, the dorsal angulation of proximal ulna has not been described in detail. While using newer straight precontoured ulnar plates, the recognition of PUDA is important anatomic landmark for surgeons treating proximal ulna fractures, nonunions, malunions or...
متن کاملThree-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography
The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...
متن کاملThe influence of lateral and anterior angulation of the proximal ulna on the treatment of a Monteggia fracture: an anatomical cadaver study.
We have investigated the anatomy of the proximal part of the ulna to assess its influence on the use of plates in the management of fractures at this site. We examined 54 specimens from cadavers. The mean varus angulation in the proximal third was 17.5 degrees (11 degrees to 23 degrees ) and the mean anterior deviation 4.5 degrees (1 degrees to 14 degrees ). These variations must be considered ...
متن کاملDistal Insertional Footprint of the Brachialis Muscle: 3D Morphometric Study
Objective. The purpose of this study is to describe the three-dimensional morphometry of the brachialis muscle at its distal attachment to the ulna. Methods. Fifty cadaveric elbows were dissected and the brachialis distal insertion was isolated on the ulna bone and probed with a three-dimensional digitizer, to create a three-dimensional model of the footprint. Measurements and analysis of each ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of shoulder and elbow surgery
دوره 21 8 شماره
صفحات -
تاریخ انتشار 2012