Three-dimensional Mach-Zehnder interferometer in a microfluidic chip for spatially-resolved label-free detection.
نویسندگان
چکیده
Ultrafast laser writing of waveguides in glasses is a very flexible and simple method for direct on-chip integration of photonic devices. In this work we present a monolithic optofluidic device in fused silica providing label-free and spatially-resolved sensing in a microfluidic channel. A Mach-Zehnder interferometer is inscribed with the sensing arm orthogonally crossing the microfluidic channel and the reference arm passing over it. The interferometer is integrated either with a microchannel fabricated by femtosecond laser technology or into a commercial lab-on-chip for capillary electrophoresis. The device layout, made possible by the unique three-dimensional capabilities of the technique, enables label-free sensing of samples flowing in the microchannel with spatial resolution of about 10 microm and limit of detection down to 10(-4) RIU.
منابع مشابه
A Review of Optical Routers in Photonic Networks-on-Chip: A Literature Survey
Due to the increasing growth of processing cores in complex computational systems, all the connection converted bottleneck for all systems. With the protection of progressing and constructing complex photonic connection on chip, optical data transmission is the best choice for replacing with electrical interconnection for the reason of gathering connection with a high bandwidth and insertion lo...
متن کاملBiosensing microsystem platform based on the integration of Si Mach-Zehnder interferometer, microfluidics and grating couplers
We have achieved the design, fabrication and packaging of microfluidic networks with photonic sensors for novel labon-chip platforms which incorporate the on-chip biosensing detection. As sensors, we used an integrated Mach-Zehnder interferometer (MZI) based on TIR waveguides (Si/SiO2/Si3N4) of micro/nanodimensions for evanescent field detection of biomolecular interactions onto the sensing are...
متن کاملA single-layer, planar, optofluidic Mach-Zehnder interferometer for label-free detection.
We have developed a planar, optofluidic Mach-Zehnder interferometer for the label-free detection of liquid samples. In contrast to most on-chip interferometers which require complex fabrication, our design was realized via a simple, single-layer soft lithography fabrication process. In addition, a single-wavelength laser source and a silicon photodetector were the only optical equipment used fo...
متن کاملNovelty low-cost integrated photonic biosensor using broadband source and on-chip spectral filter
Integrated label-free photonic biosensors provide an excellent limit of detection in combination with a low-cost disposable. Their application has thus far been limited by the necessity of an expensive tunable laser. In this article, we present a novel sensor, eliminating the tunable laser by combining a sensitive Mach-Zehnder interferometer with a broadband light source and an on-chip spectral...
متن کاملSlow light Mach-Zehnder interferometer as label-free biosensor with scalable sensitivity.
The design, fabrication, and characterization of a label-free Mach-Zehnder interferometer (MZI) optical biosensor that incorporates a highly dispersive one-dimensional (1D) photonic crystal in one arm are presented. The sensitivity of this slow light MZI-based sensor scales with the length of the slow light photonic crystal region. The numerically simulated sensitivity of a MZI sensor with a 16...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lab on a chip
دوره 10 9 شماره
صفحات -
تاریخ انتشار 2010