IMPORTANCE Bilateral vestibular failure is a debilitating condition that may lead to oscillopia and adversely affect quality of life. Researchers have suggested that vestibular function might be restored with implantation of an external mechanical stimulation device. However, it is essential that such a device must not interfere with normal hearing. OBJECTIVE To evaluate the effect of vestibular implant insertion on hearing in a sand rat model with normal hearing. DESIGN, SETTING, AND SUBJECTS The study was conducted in a tertiary medical center in accord with the guidelines of the Rabin Medical Center Animal Care and Use Committee. The experiment was performed in 6 adult, 6-month-old, fat sand rats (Psammomys obesus), which have a unique aural anatomy that permits access to the inner ear. The study dates were March 2013 to March 2014. INTERVENTIONS The sand rats were anesthetized and electrodes were implanted unilaterally (in 6 sand rats) or bilaterally (in 2 sand rats) in all 3 semicircular canals (lateral, then posterior, and then superior) by fenestration of the respective ampullas. To measure air and bone conduction thresholds, auditory nerve brainstem evoked responses to alternating polarity clicks and 1-kHz tone bursts were tested before surgery, at each operative stage, and after surgery. MAIN OUTCOMES AND MEASURES Air or bone conduction threshold shifts after implantation of a vestibular implant electrode array in each semicircular canal. RESULTS After unilateral implantation of the vestibular implant, sand rats showed a sideways head tilt, whereas after bilateral implantation, sand rats ran around in circles and were unable to stand still or walk on a treadmill. On statistical analysis, statistically significant differences from preoperative values were obtained across all stages of surgery for air conduction thresholds. The largest and statistically significant air conduction shift for 1-kHz stimuli (mean [SD, 13.7 [2.8] dB; P < .004) as well as for clicks (12.5 [2.1] dB; P < .002) was found for the superior canal electrode insertion. For the posterior canal, the air conduction thresholds to 1-kHz stimuli and to clicks shifted significantly after electrode insertion (mean [SD], 7.5 [2.3] dB; P < .01 and 7.5 [0.9] dB; P < .001). For the lateral canal, only the threshold to clicks changed significantly (mean [SD], 5.5 [1.7] dB; P < .02). Bone conduction thresholds did not change significantly after vestibular electrode insertion. CONCLUSIONS AND RELEVANCE Implantation of a vestibular device is associated with mild to moderate conductive hearing loss in fat sand rats with normal hearing, especially when the device is placed in the posterior and superior semicircular canals. Bilateral implantation is associated with major vestibular pathologic results. Further studies are needed in animals with cochlear or vestibular disorders before it can be definitively concluded that vestibular implantation carries only a minor risk to hearing.
منابع مشابه
Vestibular Evoked Myogenic Potential Produced by Bone-Conducted Stimuli: A Study on its Basics and Clinical Applications in Patients With Conductive and Sensorineural Hearing Loss and a Group With Vestibular Schawannoma
Introduction: Vestibular evoked myogenic potential (VEMP) has recently been broadly studied in vestibular disorders. As it is evoked by loud sound stimulation, even mild conductive hearing loss may affect VEMP results. Bone-conducted (BC) stimulus is an alternative stimulation for evoking this response. This study aims to assess the characteristics of BC-VEMP in different groups of patients. ...
متن کاملThe effect of cochlear implantation on the improvement of hearing performance in children suffering from profound hereditary and Non-hereditary hearing loss
Introduction: Hearing is one of the dominant senses of humans. In fact, human beings learn the language which is spoken in their environment and, then, develop the capability to speak. Cochlear implantation is introduced worldwide as a method for the treatment of the severe-to-profound sensory-neural hearing loss. Therefore, the present study aims to investigate the effect of cochlear implantat...
متن کاملFactors Associated with Vestibular Disorders in Patients with Sensorineural Hearing Loss Due to Acute Acoustic Trauma: A brief report
Background & Aim: Acute acoustic trauma is an important cause of sensorineural hearing loss (SNHL). Determination of the frequency and contributing factors for vestibular disorders is important, therefore, the current study was performed to assess these factors in patients referred to the ears, nose, and throat (ENT) clinic of one of the hospitals in Tehran, Iran, during the years 2017 to 2019....
متن کاملAcoustic Sensitivity of the Saccule and Daf Music
Introduction: The daf is a large Persian frame drum used as a musical instrument in both popular and classical music which can induce a percussive sound at low frequencies (146–290 Hz) with peaks of up to 130 dBspl. The percussive sounds have a power distribution in the region of saccular sensitivity. In view of the saccular stimulation by sound in humans, we decided to use cervical vestibu...
متن کاملCornelia De Lange Syndrome and Cochlear Implantation
Introduction: Literature regarding the different degrees of hearing loss in patients with Cornelia de Lange syndrome (CDLS) reports that half of the affected patients exhibit severe to profound sensorineural hearing loss. We present the first pre-school child with CDLS who underwent cochlear implantation for congenital profound sensorineural hearing loss. Case Report: A 3-year-old boy with CD...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JAMA otolaryngology-- head & neck surgery
دوره 141 9 شماره
صفحات -
تاریخ انتشار 2015