Cricoid pressure.

نویسندگان

  • J R Brimacombe
  • A M Berry
چکیده

PURPOSE Although cricoid pressure (CP) is a superficially simple and appropriate mechanical method to protect the patient from regurgitation and gastric insufflation, in practice it is a complex manoeuvre which is difficult to perform optimally. The purpose of this review is to examine and evaluate studies on the application of (CP). It deals with anatomical and physiological considerations, techniques employed, safety and efficacy issues and the impact of CP on airway management with special mention of the laryngeal mask airway. SOURCE OF MATERIAL: Three medical databases (48 Hours, Medline, and Reference Manager Update) were searched for citations containing key words, subject headings and text entries on CP to October 1996. PRINCIPLE FINDINGS There have been no studies proving that CP is beneficial, yet there is evidence that it is often ineffective and that it may increase the risk of failed intubation and regurgitation. After evaluation of all available data, potential guidelines are suggested for optimal use of CP in routine and complex situations. CONCLUSIONS If CP is to remain standard practice during induction of anaesthesia, it must be shown to be safe and effective. Meanwhile, further understanding of its advantages and limitations, improved training in its use, and guidelines on optimal force and method of application should lead to better patient care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cricoid pressure prevents placement of the laryngeal tube and laryngeal tube-suction II.

BACKGROUND The laryngeal tube has a potential role in patients with a difficult airway, but cricoid pressure is required if the patient is at risk of aspiration. The effect of cricoid pressure on insertion of these devices is unknown. METHODS In a randomized cross-over study, the laryngeal tube (25 patients) or the laryngeal tube-suction II (15 patients) was inserted with cricoid pressure app...

متن کامل

Cricoid pressure applied after placement of the laryngeal mask prevents gastric insufflation but inhibits ventilation.

We studied 50 patients, in a blind, crossover study, to assess if cricoid pressure applied after placement of the laryngeal mask prevented gastric insufflation without affecting ventilation. After induction of anaesthesia and neuromuscular block, a laryngeal mask was inserted and confirmed to be placed correctly. The lungs were ventilated with a maximum inflation pressure of 15 cm H2O. In the f...

متن کامل

Cricoid pressure in emergency department rapid sequence tracheal intubations: a risk-benefit analysis.

Cricoid pressure is considered an integral part of patient safety in rapid sequence tracheal intubation and emergency airway management. Cricoid pressure is applied to prevent the regurgitation of gastric contents into the pharynx and subsequent aspiration into the pulmonary tree. This review analyzes the published evidence supporting cricoid pressure, along with potential problems, including i...

متن کامل

Cricoid pressure decreases ease of tracheal intubation using fibreoptic laryngoscopy (WuScope System.

PURPOSE Cricoid pressure is commonly used during rapid sequence induction and intubation to minimize the risk of aspiration. The objective of the study was to evaluate the ease of fibreoptic (WuScope System(TM)) intubation in anesthetized adults receiving cricoid pressure. METHODS The intubation difficulty scale (IDS) was used to measure tracheal intubation difficulties in 33 patients undergo...

متن کامل

Cricoid pressure impedes placement of the laryngeal mask airway and subsequent tracheal intubation through the mask.

We have studied 40 patients to see if cricoid pressure affects the success rate of ventilation through, and the position of, the laryngeal mask and subsequent fiberscope-aided tracheal intubation. Adequate ventilation of the lungs was produced through the laryngeal mask in 19 of 20 patients in the control group, but in only 10 of 20 patients in the cricoid pressure group (P < 0.002). The laryng...

متن کامل

Fracture of the cricoid cartilage after Sellick's manoeuvre.

We report a case of fracture of the cricoid cartilage associated with cricoid pressure during rapid sequence tracheal intubation in a patient with status asthmaticus. This patient had a history of laryngeal trauma 48 yr previously. Fracture of the cricoid cartilage has not been reported previously after cricoid pressure.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 44 4  شماره 

صفحات  -

تاریخ انتشار 1997