In vivo diffusion tensor imaging of rat spinal cord at 7 T.

نویسندگان

  • Ibrahim Elshafiey
  • Mehmet Bilgen
  • Renjie He
  • Ponnada A Narayana
چکیده

In vivo diffusion tensor imaging of normal rat spinal cord was performed using a multi-segmented, blipped EPI sequence at 7 T field strength. At high diffusion weighting, the signal exhibited a non-monoexponential decay that was fitted to a biexponential function, associated with the fast and slow components of diffusion in the cord tissue, using a nonlinear regression analysis along with a constrained optimization procedure. From the measured tensors, the eigenvalues and the maps of invariant scalar measures (fractional anisotropy, relative anisotropy, volume ratio, and trace) were calculated and analyzed statistically. The results were combined to quantitatively characterize the anisotropic properties of the fast and slow diffusions in white- and gray matter of live spinal cords.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vivo Diffusion Tensor Imaging of the Rat Spinal Cord – Pilot Study

In vivo diffusion tensor imaging (DTI) of rat thoracic spinal cord was performed on five healthy rats. Axial diffusion images were obtained using a standard spin echo diffusion weighted sequence. The fractional anisotropy (FA), longitudinal (LD) and transverse (TD) diffusivities and the mean diffusivity were estimated. Differences in these parameters between white and grey matter were in accord...

متن کامل

In vivo diffusion tensor imaging of rat spinal cord with echo planar imaging.

The in vivo apparent diffusion tensor (ADT) of spinal cord was measured in nine rats at 2.0 T using an interleaved multi-shot echo planar imaging (EPI) diffusion sequence. A technique that combines sliding acquisition and phase correction, based on a calibration scan, to reduce ghosting artifacts in the images introduced by the strong diffusion-sensitizing gradients was described. Two rotationa...

متن کامل

High-resolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated, interleaved, variable-density spiral acquisition (SNAILS-DTI).

Diffusion tensor magnetic resonance imaging (DTI) is useful for studying the microstructural changes in the spinal cord following traumatic injury; however, image quality is generally poor due to the small size of the spinal cord, physiological motion and susceptibility artifacts. Self-navigated, interleaved, variable-density spiral diffusion tensor imaging (SNAILS-DTI) is a distinctive pulse s...

متن کامل

Conditions for quantitative evaluation of injured spinal cord by in vivo diffusion tensor imaging and tractography: Preclinical longitudinal study in common marmosets

Convent ional magnet ic resonance imaging (MRI) can detect hemorrhage, edema, syrinx, and spinal cord atrophy, but not axonal disrupt ion after spinal cord injury (SCI). We previously demonstrated that diffusion tensor t ractography (DTT) could depict axonal disrupt ion after hemisect ion SCI in common marmosets. In the present study, to determine the relat ionship between DTT results and funct...

متن کامل

Feasibility of 3.0 T diffusion-weighted nuclear magnetic resonance imaging in the evaluation of functional recovery of rats with complete spinal cord injury

Diffusion tensor imaging is a sensitive way to reflect axonal necrosis and degeneration, glial cell regeneration and demyelination following spinal cord injury, and to display microstructure changes in the spinal cord in vivo. Diffusion tensor imaging technology is a sensitive method to diagnose spinal cord injury; fiber tractography visualizes the white matter fibers, and directly displays the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2002