Analysis for diazepam and nordiazepam by electron-capture gas chromatography and by liquid chromatography.

نویسندگان

  • J E Wallace
  • H A Schwertner
  • E L Shimek
چکیده

We describe the use of electron-capture gas chromatography or reversed-phase "high-performance" liquid chromatography for concurrent analysis for diazepam and nordiazepam in serum. In the gas-chromatographic analysis our use of a new chemically deactivated stationary liquid phase, SP 2250-DB (Supelco, Inc.), resulted in improved chromatographic sensitivity and peak symmetry for the two benzodiazepines as compared to that obtained with either OV-17or OV-1 phases. Steady-state concentrations of diazepam and nordiazepam in serum as determined by gas-liquid chromatography correlated closely with those found by liquid-liquid chromatography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of an enzyme immunoassay for determining diazepam and nordiazepam in serum and urine.

We evaluated a commercially available enzyme immunoassay method for determining the concentration of total diazepam plus its active metabolite, nordiazepam, in small amounts of serum and urine. The coefficients of variation were 5% within assay and 8% between assay. Concentrations so measured for patients' sera correlated well with those obtained both by gas chromatography with electron-capture...

متن کامل

Micromethod for determination of diazepam by electron-capture gas-liquid chromatography.

We used 100 microliters of plasma for the determination of diazepam. After the internal standard, prazepam, is added, the serum is directly extracted with diethyl ether, the extract is evaporated, the residue is dissolved in ethanol, and the drug is measured by gas-liquid chromatography, with use of an electron capture detector. With this procedure, 2.5 ng of diazepam in the sample can be speed...

متن کامل

Benzodiazepines: toxic serum concentrations in positive enzyme immunoassay responses.

A total of 588 blood specimens collected in an emergency unit were screened for benzodiazepines (BZDs) using enzyme-multiplied immunoassay and gas chromatography. Two-hundred eighty-five samples were positive for BZDs, and 303 samples that were negative by EMIT included 20 samples with BZDs detectable by gas-liquid chromatography. A total of 15 BZDs were identified, and the most frequently occu...

متن کامل

Determination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study

Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...

متن کامل

Quantitation of benzodiazepines in whole blood by electron impact-gas chromatography-mass spectrometry.

Benzodiazepines are frequently encountered in forensic toxicology. A literature search was conducted to find a simple method using electron impact-gas chromatography-mass spectrometry (EI-GC-MS) to examine whole blood specimens for the most commonly encountered benzodiazepines in the United States. A recently published method was identified in the literature search and used as a starting point ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 7  شماره 

صفحات  -

تاریخ انتشار 1979