Biomechanical stability of bioabsorbable screws for fixation of acetabular osteotomies.

نویسندگان

  • Mark J Adamczyk
  • Tim Odell
  • Richard Oka
  • Andrew T Mahar
  • Maya E Pring
  • François D Lalonde
  • Dennis R Wenger
چکیده

The purpose of this study was to compare the biomechanical stability of triple innominate osteotomies fixed with either bioabsorbable or stainless steel screws. Triple innominate osteotomies were performed on composite hemipelves and fixed with either three 4.5-mm bioabsorbable screws or three stainless steel 4.5-mm screws. Two screws were placed from the iliac wing into the acetabular fragment, and 1 screw was placed from below the acetabular fragment into the iliac wing. Eight specimens for each screw type were biomechanically tested in an anatomical position (replicating weight bearing) and in a flexed and abducted position (replicating spica cast positioning). Specimens were cyclically loaded between 10 and 450 N to simulate the hip contact force in this population. Lower screws were then removed, and specimens were tested under identical conditions. Fragment displacement (mm) and construct stiffness (N/mm) were compared with a 2-way analysis of variance (P < 0.05). There were no significant differences between materials for fragment displacement or construct stiffness. Anatomical position showed significantly less displacement than spica position for both materials. Initial displacement in the spica position was significantly less during lower loads for stainless steel fixation. Bioabsorbable screws demonstrate comparable biomechanical stability to stainless steel screws in anatomical and spica positions at physiological loads. Flexion and abduction of the femur adversely affect the stability of the construct for both materials. Bioabsorbable screws behave similarly to steel screws when stabilizing triple innominate osteotomies and would have the advantage of not requiring a second surgery for screw removal. Confirmation of biocompatibility should be completed before widespread clinical application.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of the Fixation Stability of the Osteotomy Fragment of the Bernese Periacetabular Osteotomy of Ganz with Tonnis' Modification of Steel's Triple Innominate Osteotomy

Introduction Periacetabular osteotomies are performed for improvement of femoral head coverage in a variety of clinical scenarios. A number of osteotomies are in clinical use today, and they differ in surgical technique, amount of coverage attainable, and biomechanical strength. The use of the triple innominate osteotomy in North America was popularized by Steel. In Tonnis' modification of the ...

متن کامل

Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study.

Bioabsorbable fixation devices offer a useful option to treat small bone fractures of the hand if the prerequisite of reliable and stable osteofixation is met. We compared the stabilities of various bioabsorbable fixation devices with metallic fixation devices by using an oblique osteotomy model in radial to ulnar orientation. The 1.5-mm, self-reinforced, poly-L-lactide (SR-PLLA) pins provided ...

متن کامل

Isolated Buttress Plating of Posterior Wall Acetabular Fractures: Is it Sufficient?

Background: Conventional fixation methods of posterior wall acetabular fractures feature the use of plating and lagscrews. However, fixation of posterior wall fractures with buttress plating alone offers potential advantages by avoidingthe hardware complications related to hardware placement through the wall fragment. The purpose of this study wasto examine if buttress plating...

متن کامل

Bioabsorbable Versus Metal Screw in the Fixation of Tibial Tubercle Transfer: A Cadaveric Biomechanical Study

BACKGROUND In tibial tubercle transfer (TTT) procedures, the osteotomized and transferred tibial tubercle is usually fixed into the host bone using metal screws. PURPOSE To compare the strength of fixation provided by a single bioabsorbable screw versus a metal screw for TTT. STUDY DESIGN Controlled laboratory study. METHODS Twenty-two pairs of human cadaveric tibiae were used to compare ...

متن کامل

Biomechanical analysis of femoral tunnel pull-out angles for anterior cruciate ligament reconstruction with bioabsorbable and metal interference screws.

BACKGROUND Fixation strength of metal and bioabsorbable interference screws has not been evaluated while varying the anterior cruciate ligament graft tension angle. HYPOTHESIS There is no difference in fixation strength between 2 types of interference screws for anterior cruciate ligament graft fixation while the graft tension angle is varied relative to the femoral tunnel. STUDY DESIGN Con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of pediatric orthopedics

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2007