Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock.

نویسندگان

  • Mark D Piehl
  • James E Manning
  • Shane L McCurdy
  • Tim S Rhue
  • Keith C Kocis
  • Charles B Cairns
  • Bruce A Cairns
چکیده

OBJECTIVE Pulse contour cardiac output (PCCO) analysis is a technique for continuous cardiac output (CO) monitoring through an arterial catheter after calibration by transpulmonary thermodilution (TPTD). Studies in adults show good correlation with pulmonary artery thermodilution (PATD) CO. Data are limited in children and patients with hemodynamic instability. The objective was to determine whether TPTD CO and PCCO analysis correlate with PATD CO in a piglet model of severe hemorrhagic shock. Mixed venous oxygen saturation (SVO2) was also compared with PATD CO. DESIGN Prospective animal study. SETTING University animal research laboratory. SUBJECTS Domesticated piglets, 24-37 kg. INTERVENTIONS Hemorrhagic shock was created by graded hemorrhage in anesthetized piglets. Hemorrhage was initiated to achieve mean arterial pressure plateaus of 60, 50, 40, 30, and 20 mm Hg. MEASUREMENTS AND MAIN RESULTS CO was measured by PATD and simultaneously with two femoral artery PCCO catheters. At each mean arterial pressure plateau, one PCCO catheter was recalibrated by TPTD; the other catheter was not recalibrated during hemorrhage. TPTD CO, PCCO measurements from each catheter, and SVO2 were compared with PATD CO at each mean arterial pressure level. TPTD CO and recalibrated PCCO showed excellent correlation (r2 = .96 and .97) and small bias (+0.11 and +0.14 L/min), respectively, compared with PATD. Without recalibration, PCCO measurements were not accurate during rapid hemorrhage (r2 = .22). SVO2 decline did not correlate as well with PATD CO (r2 = .69). CONCLUSIONS TPTD CO and recalibrated PCCO analysis correlate well with PATD CO in this severe hemorrhagic shock model. The mean difference is small (<0.15 L/min) and is not clinically significant. With rapid changes in blood pressure or intravascular volume, PCCO is not accurate unless recalibrated by TPTD CO. SVO2 did not correlate well with CO in this model.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of ATP-MgCl2-hypertonic solution (NaCl5%) administration on hemorrhagic shock

Introduction: In the recent years, effect of hypertonic solution in resuscitation of shock has been shown by clinical and laboratory studies. On the other hand ATP-MgCl2 is used for better tissue perfusion and cardiac output in shock. The aim of this study is evaluation of ATP-MgCl2 with hypertonic solution in resuscitation of hemorrhagic shock. Materials and Methods: In this experimental stud...

متن کامل

Administration of Large Volume Hypertonic Solutions for Resuscitation of Hemorrhagic Shock in Rabbit

An animal model was designed to study the effect of large volume Hypertonic Solutions (HTS) for re‌suscitation following a hypovolemic shock. Resuscitation in hypovolemic animals was performed by infusion of 15 ml/kg of normal saline (group I), 5% sodium bicarbonate (NaHCO3) (group II), 5% sodium chloride (NaCI) and 7.5 % NaHCO3 1:1 VN (group III), 5% NaC1 (group IV), and 5% NaCl and 5% serum a...

متن کامل

Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis.

BACKGROUND Recently, continuous monitoring of cardiac output (CO) based on pulse contour analysis (Vigileo) has been introduced into practice. In this clinical study, we evaluated the accuracy of this system by comparing it with the transpulmonary thermodilution technique (TPID) in septic patients. METHODS We studied 24 mechanically ventilated patients with septic shock (16 male, 8 female, ag...

متن کامل

Adrenal pheochromocytoma presenting with Takotsubo-pattern cardiomyopathy and acute heart failure

BACKGROUND Pheochromocytoma is an endocrine tumor that causes hypertension, facial pallor, and headache. Pheochromocytoma patients rarely present with acute heart failure or cardiogenic shock. METHOD We discuss the case of a female patient with Takotsubo-pattern cardiomyopathy who presented with acute heart failure caused by pheochromocytoma. RESULT Treatment was adjusted based on the data ...

متن کامل

Pulse contour analysis: Is it able to reliably detect changes in cardiac output in the haemodynamically unstable patient?

Three pulse contour systems for monitoring cardiac output - LiDCO Plus™, PiCCO Plus™ and FloTrac™ - were compared in postcardiac surgery patients. None of the three methods demonstrated good trending ability according to concordance analysis. Pulse contour systems remain unreliable in the haemodynamically unstable patient.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Critical care medicine

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2008