Scintillation detectors for x-rays
نویسنده
چکیده
Recent research in the field of phosphor and scintillator materials and related detectors is reviewed. After a historical introduction the fundamental issues are explained regarding the interaction of x-ray radiation with a solid state. Crucial parameters and characteristics important for the performance of these materials in applications, including the employed measurement methods, are described. Extended description of the materials currently in use or under intense study is given. Scintillation detector configurations are further briefly overviewed and selected applications are mentioned in more detail to provide an illustration.
منابع مشابه
Development of a Compton camera for medical applications based on silicon strip and scintillation detectors
A Compton camera is being developed for the purpose of ion-range monitoring during hadrontherapy via the detection of prompt-gamma rays. The system consists of a scintillating fiber beam tagging hodoscope, a stack of double sided silicon strip detectors (90×90×2 mm, 2×64 strips) as scatter detectors, as well as bismuth germanate (BGO) scintillation detectors (38×35×30 mm, 100 blocks) as absorbe...
متن کاملThe Energy Resolution of Xenon-Neon filled Gas Proportional-Scintillation Counters for X-Rays Below 2 keV
The energy spectra of x-rays with energies below 2 keV measured at atmospheric pressure with standard Xe gas detectors, such as gas proportional-scintillation counters (GPSC), exhibit distortions that are related to losses of electrons and fluorescence photons to the radiation window. In this work, a Monte Carlo simulation method that takes into account these losses investigates the use of Xe-N...
متن کاملSimulation Calibration of an Extensive Air Shower array, by a logged data set of its small prototype
Alborz observatory is an EAS array in the heights of Alborez mountain chain near Tehran. For the development of the array, more number of detectors is inevitable. The managing the financial resources and achieving the highest efficiency of the array is important for the project. Therefore, Water Cherenkov Detectors has been used for 9 months in the same way as the previous experiment with Scint...
متن کاملGrowth of CsI(Tl) crystals doped with Ca and Tm and investigation of its scintillation characteristics
In this work, the growth of CsI(Tl) crystals as gamma detector was performed using vertical Bridgman method with Ca and Tm co-dopants. For evaluation of the growth crystals, X-Ray Diffraction (XRD), photoluminescence and thermoluminescence spectra as well as recorded gamma spectra were employed. In addition, the scintillation properties including energy resolution, scintillation decay time, abs...
متن کاملXenon–Neon Gas Proportional-Scintillation Counters for X-Rays Below 2 keV: A Monte Carlo Simulation Study
The energy spectra of X-rays with energies below 2 keV measured at atmospheric pressure with standard Xe gas detectors, such as gas proportional-scintillation counters, exhibit distortions that are related to losses of electrons and fluorescence photons to the radiation window. In this paper, a Monte Carlo simulation method that takes into account these losses investigates the use of Xe–Ne mixt...
متن کامل