Performance characteristics between TDx®FLx and TBA™-25FR for the therapeutic drug monitoring of methotrexate.

نویسندگان

  • Tetsuya Kaneko
  • Takashi Fujioka
  • Yosuke Suzuki
  • Yuhki Sato
  • Hiroki Itoh
چکیده

BACKGROUND High-dose methotrexate (HDMTX) is used in the treatment of certain malignancies, including leptomeningeal metastases, systemic non-Hodgkin lymphoma, acute lymphoblastic leukemia, and osteosarcoma. High circulating levels of methotrexate can cause severe myelosuppression. The present study aimed to examine the differences in plasma MTX concentrations measured by two immunoassay systems currently available in the Japanese market, a TDX/FLX analyzer and a TBA-25FR analyzer. METHODS A total of 69 plasma samples from 16 patients were assayed by a fluorescence polarization immunoassay technique using a TDx/FLx analyzer (Abbott Diagnostics, Chicago, Illinois, U.S.A.) and a homogeneous enzyme immunoassay technique using a TBA-25FR analyzer (Toshiba Medical Systems, Tokyo, Japan). RESULTS Assay results were very consistent between the two systems, with good correlation 24 h after the start of treatment (TBA-25FR = 1.06・TDX/FLX, -1.31, r = 0.99), 48 h after the start of treatment (TBA-25FR = 1.00・TDX/FLX, +0.027, r > 0.99), and 72 h after the start of treatment (TBA-25FR = 1.09・TDX/FLX, +0.011, r > 0.99). CONCLUSIONS The calibration curve spanned one order of magnitude with a linear working range from the lowest to the highest standard. The standard deviations show the excellent reproducibility of repeated measurements at each standard level for both immunoassay systems. However, when using the TBA-25FR, it is necessary to perform measurements in the low-concentration range with care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ion Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation

Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The...

متن کامل

Physicochemical Characterization of Altebrel™, a Proposed Etanercept Biosimilar

Background: Etanercept is prescribed for the rapid and effective treatment of chronic immune-mediated inflammatory disorders. Due to the expiration of etanercept patents and worldwide demand for comparable and more affordable substitutes, several biosimilars of etanercept have been approved in different countries and new ones are in the process of approval.Objectives: In the present study...

متن کامل

High-Performance Liquid Chromatography Determination of Methotrexate in Plasma

This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...

متن کامل

High-Performance Liquid Chromatography Determination of Methotrexate in Plasma

This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...

متن کامل

A Review on Therapeutic Drug Monitoring of Immunosuppressant Drugs

Immunosuppressants require therapeutic drug monitoring because of their narrow therapeutic index and significant inter-individual variability in blood concentrations. This variability can be because of factors like drug-nutrient interactions, drug-disease interactions, renal-insufficiency, inflammation and infection, gender, age, polymorphism and liver mass. Drug monitoring is widely practiced ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical health care and sciences

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2016