A phantom study investigating the relationship between ground‐glass opacity visibility and physical detectability index in low‐dose chest computed tomography
نویسندگان
چکیده
In this study, the relationship between ground-glass opacity (GGO) visibility and physical detectability index in low-dose computed tomography (LDCT) for lung cancer screening was investigated. An anthropomorphic chest phantom that included synthetic GGOs with CT numbers of -630 Hounsfield units (HU; high attenuation GGO: HGGO) and -800 HU (low attenuation GGO: LGGO), and three phantoms for physical measurements were employed. The phantoms were scanned using 12 CT systems located in 11 screening centers in Japan. The slice thicknesses and CT dose indices (CTDI(vol)) varied over 1.0-5.0 mm and 0.85-3.30 mGy, respectively, and several reconstruction kernels were used. Physical detectability index values were calculated from measurements of resolution, noise, and slice thickness properties for all image sets. Five radiologists and one thoracic surgeon, blind to one another's observations, evaluated GGO visibility using a five-point scoring system. The physical detectability index correlated reasonably well with the GGO visibility (R² = 0.709, p < 0.01 for 6 mm HGGO and R² = 0.646, p < 0.01 for 10 mm LGGO), and was nearly proportional to the CTDI(vol). Consequently, the CTDI(vol) also correlated reasonably well with the GGO visibility (R² = 0.701, p < 0.01 for 6 mm HGGO and R² = 0.680, p < 0.01 for 10 mm LGGO). As a result, the CTDI(vol) was nearly dominant in the GGO visibility for image sets with different reconstruction kernels and slice thicknesses, used in this study.
منابع مشابه
Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
متن کاملEffect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations
Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...
متن کاملThorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
Background: This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...
متن کاملIdentification of preoperative prediction factors of tumor subtypes for patients with solitary ground-glass opacity pulmonary nodules
BACKGROUND Recent wide spread use of low-dose helical computed tomography for the screening of lung cancer have led to an increase in the detection rate of very faint and smaller lesions known as ground-glass opacity nodules. The purpose of this study was to investigate the clinical factors of lung cancer patients with solitary ground-glass opacity pulmonary nodules on computed tomography. ME...
متن کاملDistribution of the radiation dose in multislice computer tomography of the chest – phantom study
BACKGROUND The most commonly used form of reporting doses in multislice computed tomography involves a CT dose index per slice and dose-length product for the whole series. The purpose of this study was to analyze the actual dose distribution in routine chest CT examination protocols using an antropomorphic phantom. MATERIAL/METHODS We included in the analysis readings from a phantom filled w...
متن کامل