A comparison of tympanic and rectal temperatures in term NIGERIAN neonates

نویسندگان

  • Chika O Duru
  • Felix O Akinbami
  • Adebola E Orimadegun
چکیده

BACKGROUND Tympanic thermometry has come as a suitable alternative to traditional thermometry because of its safety and ease of use. However, it is still yet to gain wide acceptance in African settings due to conflicting results on its accuracy, thus rectal thermometry remains the gold standard in the newborn. The aim of this study was to compare tympanic and rectal temperatures in term Nigerian neonates. METHODS Rectal and tympanic temperatures were measured simultaneously in 300 consecutive term neonates between the ages of 37 and 42 weeks gestation using mercury-in-glass and the Infrared tympanic thermometers respectively. Paired t test, Pearson correlation coefficient and the Bland-Altman plot were used to compute data. Using rectal thermometry as gold standard, the sensitivity, specificity and predictive values of tympanic thermometry at various rectal temperature cut-offs were determined. Receiver Operating Curves (ROC) were constructed and the Areas Under the Curves (AUC) were compared. RESULTS The mean rectal temperature (37.34±0.55°C) was significantly higher than the mean tympanic temperature (37.25 ± 0.56°C) (p<0.001) with a mean difference of 0.09 °C±0.24 °C (95% CI: 0.06, 0.12). There was a strong positive correlation between the two measurements (r=0.9; p<0.001). Tympanic thermometry showed sensitivities ranging from 65% to 86% and specificities of 95% to 99% at rectal temperature cut-offs of 37.5°C to 38°C. The positive and negative predictive values of the tympanic temperatures at the various temperature cut-offs ranged from 82% to 93% and 80% to 98% respectively. Accuracy was noted to increase with higher temperatures as shown by the Receiver Operating Curves with the highest accuracy at the temperature cut-off of 38°C and AUC of 0.91. CONCLUSIONS The sensitivity of tympanic thermometry was relatively low in detecting rectal temperatures despite the good correlation and agreement between them. The specificities and predictive values of tympanic temperatures in detecting rectal temperatures were high and accuracy increased with higher temperatures. Though using the tympanic route for measuring temperature in the newborn is relatively safe and non-invasive, its low sensitivity limits its use. Further studies would be required to further assess the accuracy of tympanic temperature measurements in the newborn.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی صحت و دقت دمای تمپانیک در بازتاب دمای مرکزی بدن

  Background & Aim: Monitoring of patients' temperature is an important nursing clinical procedure. Body temperature is usually taken at different sites including pulmonary artery, rectal, oral, and axillary areas. Currently, infrared tympanic temperature measurement method is increasingly used as a convenient, noninvasive and rapid method. However, accuracy and precision of this method has bee...

متن کامل

بررسی مقایسه‌ای میزان درجه حرارت مری، گوش و مقعد در کودکان تحت جراحی قلب باز

Introduction: cardiac surgery by cardiopulmonary bypass (CPB) is performed accompanying with hypothermia. Measuring the body temperature during hypothermia is very important. The aim of this study was to compare esophageal, tympanic and rectal temperatures in pediatric patients below 12 years old undergoing open heart surgery. Methods: This study was a cross-sectional descriptive and analytic ...

متن کامل

A Comparative Study on Temperature Accuracy between Tympanic, Rectal, and Axillary Sites

A new method recently used for measuring the temperature is using tympanic thermometer. The aim of this study was to compare the accuracy of this method with rectal and axillary measurement in children less than 6 years old. A total of 220 pair ears, axillaries, and rectal sites were used to determine the body temperature in patients aged between 3 months to 6 years who referred to Emergency De...

متن کامل

Accuracy of a noninvasive temporal artery thermometer for use in infants.

OBJECTIVES To assess the accuracy of a new noninvasive temporal artery (TA) thermometer in infants; to compare the accuracy of the TA thermometer with that of a tympanic thermometer, using rectal thermometry as the criterion standard; and to compare the tolerability of the TA thermometer with that of the tympanic and rectal thermometers. DESIGN Prospective evaluation of the accuracy of TA and...

متن کامل

Intestinal Bacterial Colonization in the First 2 Weeks of Life of Nigerian Neonates Using Standard Culture Methods

OBJECTIVE The pattern and timing of development of intestinal microflora in Nigerian infants have been scarcely researched. This study was carried out to investigate the bacteria flora in the rectum of healthy neonates in Ibadan, Nigeria. PATIENTS AND METHODS In this hospital-based longitudinal study, rectal swabs of 70 neonates were taken within 6-12 h of birth (day 1) and subsequently on da...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012