Effects of eyelid closure and disposable and silicone hydrogel extended contact lens wear on rabbit corneal epithelial proliferation.

نویسندگان

  • Patrick M Ladage
  • David H Ren
  • W Matthew Petroll
  • James V Jester
  • Jan P G Bergmanson
  • H Dwight Cavanagh
چکیده

PURPOSE To examine the rabbit corneal epithelial cell proliferation rate after extended wear of disposable or silicone hydrogel contact lenses or prolonged eyelid closure. METHODS One randomly chosen eye of 40 New Zealand White rabbits was assigned to silicone hydrogel contact lens wear (n = 15, SH), disposable hydrogel contact lens wear (n = 6, DH), eyelid suturing (n = 15, SUT), or no intervention (n = 4). Contralateral eyes served as the control. After 24 hours or 1 week of lens wear, 5-bromo-2-deoxyuridine (BrdU) was injected intravenously to label dividing corneal epithelial cells, and animals were killed 24 hours after injection. Corneas were stained with monoclonal anti-BrdU antibody and FITC-conjugated secondary antibody. A series of continuous digital images of the wholemounted epithelium were collected from the superior to inferior limbus, and the number of BrdU-labeled cell pairs was counted. RESULTS SH, DH, and SUT caused a significant decrease in BrdU-labeled pairs of cells over the entire corneal epithelium at day 2 compared with the number in contralateral control eyes (P < 0.001). One week of SUT or SH caused a significant increase centrally in BrdU-labeled cells (P < 0.01). BrdU labeling at the limbus in all groups was not significantly different from the control. Unexpectedly, the proliferation rate of the control corneas was also significantly affected by contralateral lens wear and suturing. CONCLUSIONS Short-term overnight SH, DH, and SUT all significantly suppressed the cell proliferation rate in the rabbit corneal epithelium. However, adaptation, with central hyperproliferation of cells, appeared to occur at 8 days. The effects of lens wear and eyelid suturing on the cell proliferation rate in contralateral control eyes suggests a central mechanism that regulates corneal epithelial proliferation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence of keratitis of varying severity among contact lens wearers.

AIM To determine the incidence of non-severe keratitis (NSK) and severe keratitis (SK) among wearers of current generation contact lenses. METHODS A 12 month, prospective, hospital based epidemiological study was conducted by examining all contact lens wearers presenting with a corneal infiltrate/ulcer to a hospital centre in Manchester. A clinical severity matrix was used to differentiate be...

متن کامل

The effect of nonpreserved care solutions on 12 months of daily and extended silicone hydrogel contact lens wear.

PURPOSE To determine the effects of nonpreserved care solutions on human corneal epithelium in long-term daily wear (DW) compared with overnight (extended) wear (EW) of hyper-oxygen-permeable silicone hydrogel contact lenses. METHODS This was a prospective, randomized, double-masked, single-center, parallel treatment group clinical trial (NCT 00344643). One hundred twenty-one patients complet...

متن کامل

The ocular response to extended wear of a high Dk silicone hydrogel contact lens.

PURPOSE A four-month extended wear clinical trial was conducted to compare the ocular effects of a high Dk Balafilcon A silicone hydrogel lens and a low Dk HEMA 38.6 per cent H20 soft lens. METHOD Twenty-four subjects who were adapted to daily wear of soft lenses wore a high Dk lens in one eye and a low Dk HEMA lens in the other eye for four months on an extended wear basis after one week of ...

متن کامل

Corneal epithelial permeability during extended wear of disposable contact lenses versus daily wear of soft contact lenses.

AIMS The corneal epithelial permeability during extended wear of disposable contact lenses was compared with that during daily wear of soft contact lenses. The study was performed to verify whether the extended wear of disposable contact lenses would result in a higher permeability value than the daily wear of soft contact lenses. A higher permeability makes the cornea more vulnerable for bacte...

متن کامل

Mixed infection (Pseudomonas and coagulase negative staphylococci) microbial keratitis associated with extended wear silicone hydrogel contact lens.

Contact lens induced ulcerative keratitis is a serious complication which can be devastating for the patient if treatment is delayed. Extended wear is the commonest cause of microbial keratitis in contact lens wear. New extended wear silicone hydrogel contact lenses have higher oxygen transmissibility so that they can be worn continuously for 30 days. They can also be used as bandage contact le...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 44 5  شماره 

صفحات  -

تاریخ انتشار 2003