Inhaler technique blind spot

نویسندگان

  • D. Stanescu
  • G. Viegi
چکیده

We would like to thank D. Stanescu for giving us the opportunity to clarify the definition of airflow obstruction recently given in the interpretative strategies document from the American Thoracic Society/European Respiratory Society (ERS) Task Force [1]. The document states that in most cases a ratio of forced expiratory volume in one second (FEV1) to vital capacity (VC) below the lower limits of normality is the parameter that best and most frequently embodies the concept of airflow obstruction with few exceptions. However, in some cases, a low FEV1 with a normal FEV1/VC may also be consistent with an obstructive pattern if total lung capacity is normal. This pattern has been observed after exposing the airways to a constrictor agent [2, 3] or in natural respiratory diseases [4], reproduced in healthy subjects [5, 6], and has already been interpreted as consistent with airway narrowing in the 1993 ERS guidelines on lung function testing [7]. The fact that this may be caused by a patchy collapse of the small airways on early expiration or expiratory flow limitation that, in turn, would cause an increase in residual volume was suggested by OLIVE and HYATT [2] in 1972 and then by other investigators in the years that followed [3, 5, 6]. However, this hypothesis still needs confirmation, especially after the demonstration that even the large airways may close with induced bronchoconstriction [8], thus suggesting that the small airways are not the only ones that may contribute towards the generation of air trapping and an increase in residual volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Providing information on metered dose inhaler technique: is multimedia as effective as print?

BACKGROUND Metered dose inhalers (MDIs) are not easy to use well. Every MDI user receives a manufacturer's patient information leaflet (PIL). However, not everyone is able or willing to read written information. Multimedia offers an alternative method for teaching or reinforcing correct inhaler technique. OBJECTIVE The aim of this study was to compare the effects of brief exposure to the same...

متن کامل

A protocol for a randomised clinical trial of the effect of providing feedback on inhaler technique and adherence from an electronic device in patients with poorly controlled severe asthma

INTRODUCTION In clinical practice, it is difficult to distinguish between patients with refractory asthma from those with poorly controlled asthma, where symptoms persist due to poor adherence, inadequate inhaler technique or comorbid diseases. We designed an audio recording device which, when attached to an inhaler, objectively identifies the time and technique of inhaler use, thereby assessin...

متن کامل

Evaluation of inhalation aids of metered dose inhalers in asthmatic children.

Many patients have incorrect aerosol inhalation technique with metered dose inhalers (MDI). Several inhalation aids have been developed and marketed for these patients. Even those who have correct inhalation technique may benefit from these devices. We compared bronchodilator efficacy of two puffs of albuterol aerosol administered either directly from a MDI mouthpiece, or from an inhalation aid...

متن کامل

بررسی میزان کاربرد صحیح انواع اسپری استنشاقی توسط پزشکان ، داروسازان و پرستاران شاغل در بیمارستاهای آموزشی شهر همدان

Poor inhaler technique is a common problem both in asthma patients and health care providers , which contributes to poor asthma control. The aim of this study was to evaluate the correctness of metered-dose inhaler (MDI) technique in a sample of physicians , pharmacists and nurses practicing in Hamadan University hospitals. A total of 176 healthcare providers (35 internis...

متن کامل

A cross-sectional observational study to assess inhaler technique in Saudi hospitalized patients with asthma and chronic obstructive pulmonary disease

OBJECTIVES To assess the proportion of critical errors committed while demonstrating the inhaler technique in hospitalized patients diagnosed with asthma and chronic obstructive pulmonary disease (COPD).  METHODS This cross-sectional observational study was conducted in 47 asthmatic and COPD patients using inhaler devices. The study took place at King Abdulaziz Medical City, Riyadh, Saudi Ara...

متن کامل

Inhibition by sodium cromoglycate of bronchoconstriction stimulated by respiratory heat loss: comparison of pressurised aerosol and powder.

The protective effect was examined of three doses (2, 10, and 20 mg) of sodium cromoglycate inhaled from a pressurised metered dose inhaler on the response to isocapnic hyperventilation of cold dry air in 10 asthmatic subjects. This was compared with the effect of cromoglycate powder (20 mg) inhaled from a Spincap and with placebo given on two occasions. The medications were inhaled on separate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006