Validation of GEANT 4 Monte Carlo models with a highly granular scintillator - steel hadron calorimeter
نویسنده
چکیده
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8 GeV to 100 GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.
منابع مشابه
Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter The CALICE Collaboration
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results a...
متن کاملTrack segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter
c CERN 2013 for the benefit of the CALICE collaboration, published under the terms of the Creative Commons Attribution 3.0 License by IOP Publishing Ltd and Sissa Medialab srl. Any further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation and DOI. ABSTRACT: We investigate the three dimensional substructure of hadronic shower...
متن کاملComparison of Fluka-2006 Monte Carlo Simulation and Flight data for the ATIC detector
We have performed a detailed Monte Carlo (MC) simulation for the Advanced Thin Ionization Calorimeter (ATIC) detector using the MC code FLUKA-2006 which is capable of simulating particles up to 10 PeV. The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon flight, investi...
متن کاملNon-Compensation of the Barrel Tile Hadron Module-0 Calorimeter
The detailed experimental information about the electron and pion responses, the electron energy resolution and the e/h ratio as a function of incident energy E, impact point Z and incidence angle Θ of the Module-0 of the iron-scintillator barrel hadron calorimeter with the longitudinal tile configuration is presented. The results are based on the electron and pion beams data for E = 10, 20, 60...
متن کاملElectron Response and e/h Ratio of Iron-Scintillator Hadron Prototype Calorimeter with Longitudinal Tile Configuration
The detailed information about electron response, electron energy resolution and e/h ratio as a function of incident energy E, impact point Z and incidence angle Θ of iron-scintillator hadron prototype calorimeter with longitudinal tile configuration is presented. These results are based on electron and pion beams data of E = 20, 50, 100, 150, 300 GeV at Θ = 10, 20, 30, which were obtained duri...
متن کامل