Pseudomonas aeruginosa in a neonatal intensive care unit: molecular epidemiology and infection control measures

نویسندگان

  • Valeria Crivaro
  • Anna Di Popolo
  • Alessandro Caprio
  • Antonietta Lambiase
  • Mario Di Resta
  • Tonia Borriello
  • Alda Scarcella
  • Maria Triassi
  • Raffaele Zarrilli
چکیده

BACKGROUND Pseudomonas aeruginosa, a non-fermentative, gram-negative rod, is responsible for a wide variety of clinical syndromes in NICU patients, including sepsis, pneumonia, meningitis, diarrhea, conjunctivitis and skin infections. An increased number of infections and colonisations by P. aeruginosa has been observed in the neonatal intensive care unit (NICU) of our university hospital between 2005 and 2007. METHODS Hand disinfection compliance before and after an educational programme on hand hygiene was evaluated. Identification of microrganisms was performed using conventional methods. Antibiotic susceptibility was evaluated by MIC microdilution. Genotyping was performed by PFGE analysis. RESULTS The molecular epidemiology of Pseudomonas aeruginosa in the NICU of the Federico II University hospital (Naples, Italy) and the infection control measures adopted to stop the spreading of P. aeruginosa in the ward were described. From July 2005 to June 2007, P. aeruginosa was isolated from 135 neonates and caused severe infections in 11 of them. Macrorestriction analysis of clinical isolates from 90 neonates identified 20 distinct genotypes, one major PFGE type (A) being isolated from 48 patients and responsible for 4 infections in 4 of them, four other distinct recurrent genotypes being isolated in 6 to 4 patients. Seven environmental strains were isolated from the hand of a nurse and from three sinks on two occasions, two of these showing PFGE profiles A and G identical to two clinical isolates responsible for infection. The successful control of the outbreak was achieved through implementation of active surveillance of healthcare-associated infections in the ward together with environmental microbiological sampling and an intense educational programme on hand disinfection among the staff members. CONCLUSION P. aeruginosa infections in the NICU were caused by the cross-transmission of an epidemic clone in 4 neonates, and by the selection of sporadic clones in 7 others. An infection control programme that included active surveillance and strict adherence to hand disinfection policies was effective in controlling NICU-acquired infections and colonisations caused by P. aeruginosa.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imipenem-resistant Pseudomonas aeruginosa strains carry vim-type metallo-beta-lactamases isolated from intensive care unit, Shahid Beheshti Hospital, North of Iran

Background: Pseudomonas aeruginosa is the causing agent of many hospital infections and metallo-beta-lactamases (MBL) are being reported with increasing frequency. The aim of this study was to determine the frequency of metallo-&beta-lactamases (MBL) and VIM-1 gene in multidrug-resistant strains of P. aeruginosa isolates and to compare the methods of phenotypic and molecular detection. Materia...

متن کامل

Molecular Epidemiology of Pseudomonas aeruginosa in the Intensive Care Units – A Review

Pseudomonas aeruginosa is one of the leading nosocomial pathogens in intensive care units (ICU). This opportunist pathogen is commonly recovered from moist environments, and is also found colonizing 2.6 to 24% of hospitalized patients. We reviewed the recent literature that used highly discriminatory typing methods to precisely identify the reservoirs and modes of transmission of this microorga...

متن کامل

عفونت‌های بیمارستانی و عوامل باکتریایی آنها: بخش مراقبت‌های ویژه نوزادان بیمارستان دانشگاهی قائم (عج) مشهد

Background: Nosocomial infections increase patients' morbidity, mortality and length of hospital stay especially in neonatal intensive care units (NICUs) and have become a matter of major concern. Controlling and preventing nosocomial infections need enough information about epidemiology of these infections. This study aims at estimating the incidence rate and the most frequent bacteria which c...

متن کامل

Outbreak of Pseudomonas aeruginosa in a Neonatal Intensive Care Unit: Are Point-of-Use Filters Useful?

Pseudomonas aeruginosa, in intensive care units (ICUs), causes infections with high morbidity and mortality rates. Tap water outlets are often contaminated with P.aeruginosa and may represent a source of endemic infections in ICUs. The aim of this study was to explore the role of point-of-use (POU) filters in neonatal intensive care unit (NICU) in reducing P.aeruginosa colonizations/infections....

متن کامل

Contamination of a milk bank pasteuriser causing a Pseudomonas aeruginosa outbreak in a neonatal intensive care unit.

An environmental investigation and a cohort study were carried out to analyse an outbreak of infection caused by a serotype O10 Pseudomonas aeruginosa in a neonatal intensive care unit. Thirty one cases of infection were recorded, including four lethal ones. The outbreak was stopped by eradicating the environmental sources: a contaminated milk bank pasteuriser and bottle warmer.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009