A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis
نویسندگان
چکیده
BACKGROUND Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. METHODS Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. RESULTS In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8-98.3), Onsite 92.5%(90.3-94.3), DPP 89.8%(87.3-91.9) and Bioline 87.8%(85.1-90.0). Specificities were: Determine 96.4%(94.1-97.8), Onsite 92.5%(90.3-94.3), DPP 98.3%(96.5-99.2), and Bioline 98.5%(96.8-99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4-90.2%) compared to secondary syphilis (94.3-98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR ≥ 8) (range: 94.6-99.5%) than RPR non-reactive infections (range: 76.3-92.9%). CONCLUSIONS The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would need to be supplemented with additional tests among populations where syphilis incidence is high to avoid missing early syphilis cases.
منابع مشابه
Multisite Laboratory Evaluation of a Dual Human Immunodeficiency Virus (HIV)/Syphilis Point-of-Care Rapid Test for Simultaneous Detection of HIV and Syphilis Infection
BACKGROUND Recently, test developers have created rapid point-of-care tests that can simultaneously detect multiple infections within the same specimen using a single device. The SD BIOLINE Duo HIV/Syphilis rapid point-of-care test uses a solid-phase immunochromatographic assay to detect immunoglobulin (Ig)G, IgM, and IgA antibodies to human immunodeficiency virus (HIV)-specific antigens (HIV-1...
متن کاملForm II HRP Research Proposal: Project details Utility evaluation of Point-of-Care Tests in Non-Clinical Settings for the Screening of HIV and Syphilis in Men Who Have Sex with Men 1. Project summary
Serologic tests are the diagnostic tests of choice for HIV and syphilis. There are two types of serological tests (treponemal and non-treponemal tests) for laboratory diagnosis of syphilis. Traditionally, one non-treponemal assay is used for screening and a treponemal assay is used for confirmation for syphilis. For diagnosis of HIV EIAs are used for screening and Western blot for confirmation ...
متن کاملEvaluation of the diagnostic performance and operational characteristics of four rapid immunochromatographic syphilis tests in Burkina Faso.
BACKGROUND AND OBJECTIVE Little information is available on the rapid diagnostic testing for syphilis in Burkina Faso. The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health wo...
متن کاملDiagnostic accuracy of a point-of-care syphilis test when used among pregnant women in Bolivia.
OBJECTIVE To evaluate the performance of a point-of-care (POC) syphilis test when used in urban Bolivian maternity hospitals. METHODS We tested 8892 pregnant women for syphilis using the Abbott Determine Syphilis TP rapid POC test and rapid plasma reagin (RPR) in the laboratory of four large urban maternity hospitals where national statistics reported a syphilis prevalence of at least 3%. Ser...
متن کاملAre Treponema pallidum Specific Rapid and Point-of-Care Tests for Syphilis Accurate Enough for Screening in Resource Limited Settings? Evidence from a Meta-Analysis
BACKGROUND Rapid and point-of-care (POC) tests for syphilis are an invaluable screening tool, yet inadequate evaluation of their diagnostic accuracy against best reference standards limits their widespread global uptake. To fill this gap, a systematic review and meta-analysis was conducted to evaluate the sensitivity and specificity of rapid and POC tests in blood and serum samples against Trep...
متن کامل