Evaluation of Ames' "Clini-Tek".

نویسندگان

  • J D Peele
  • R H Gadsden
  • R Crews
چکیده

Reproducibility of reading "N-Multistix" dipsticks by a semi-automated urinalysis instrument (Ames' "Clini-Tek") has been described for artifically prepared samples. Glucose, ketone, urobilinogen, and nitrite showed high reproducibility (greater than 90%) for reading multiple samples at predetermined analyte concentrations. Determination of proteinuria showed the lowest proportion of false positives (2-3%) and false negatives (0%). Determination of hemoglobinuria and bilirubinuria by dipsticks were the least reproducible. Urobilinogen showed no interference from bilirubin in concentrations up to 32 mg/liter. Precision was high for results for quality-control capsules provided by the manufacturer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Mutagenic Potentials of Some Food Additives by Ames Test

Some chemicals used by human such as food additives are mutagenic and mutagenicity effects analysis of them is very important because of considerable consumption by man. One of the most common methods used in the recognition of the chemicals' mutagenicity is Salmonella Typhimurium Reverse Mutation (Ames) test. The purpose of the present study is mutagenicity effects analysis of sodium nitrite, ...

متن کامل

Nontuberculous ( Environmental ) Mycobacterial Disease 12

12 Nontuberculous mycobacteria (NTM) are in the same family as the organisms that cause tuberculosis and leprosy, but unlike those organisms, NTM are widely dispersed in our environment, vary greatly in their ability to cause disease, and are not spread from person to person. There are about 140 different species of mycobacteria. Mycobacteria not closely related to tuberculosis or leprosy are c...

متن کامل

Clinician's Commentary on Hall et al.1

It is well established that clinical education (CE) is a vital part of entry into practice training for physiotherapy students. This form of education depends on the willingness of clinicians to take on a supervisory or instructor role. Educational programmes are increasingly being challenged to find quality placements, and larger class sizes are putting further demands on these already scarce ...

متن کامل

Evaluation of Mutagenicity of Mebudipine, a New Calcium Channel Blocker

Mebudipine is a new dihydropyridine calcium channel blocker, synthesized in our laboratory, for treatment of hypertension. It has shown a better efficacy than other drugs in this group. For assessing the risks of this drug, certain safety tests in the preclinical stage have been performed. In this study mutagenic effect of mebudipine was evaluated using Ames assay that could assess the mutageni...

متن کامل

Evaluation of Mutagenicity of Mebudipine, a New Calcium Channel Blocker

Mebudipine is a new dihydropyridine calcium channel blocker, synthesized in our laboratory, for treatment of hypertension. It has shown a better efficacy than other drugs in this group. For assessing the risks of this drug, certain safety tests in the preclinical stage have been performed. In this study mutagenic effect of mebudipine was evaluated using Ames assay that could assess the mutageni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 12  شماره 

صفحات  -

تاریخ انتشار 1977