Design of Meander Antenna for UHF Partial Discharge Detection of Transformers

نویسندگان

  • Mengjie Li
  • Chuangxin Guo
  • Ziping Peng
چکیده

Ultra high frequency (UHF) partial discharge (PD) detection approaches take advantages of strong anti-interference ability, and have been considered as a promising technology for online monitoring PD signals. This paper presents a meander antenna with wide frequency band and small size for UHF PD detection in power transformers. The optimal geometric parameters of the meander antenna were obtained through the parametric investigation. A prototype of the proposed antenna was fabricated. Actual PD experiments were carried out for typical artificial insulation defect models while the antenna was used for PD measurements. The experimental results show that the proposed meander antenna is suitable and effective for UHF online monitoring of PDs in transformers. Copyright © 2014 IFSA Publishing, S. L.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی عملکرد پروب‌های UHF در آشکارسازی تخلیه جزئی در ترانسفورماتورهای فشار قوی

Recently, UHF partial discharge (PD) detection on power transformers attracts lots of attentions. For the transformers already installed in power network, the UHF signals can be captured only by UHF probes installed through oil drain valve. Although UHF probes are commercially produced, there are a lot of missing information on characteristics and features of these probes for PD detection. In t...

متن کامل

Calibration of UHF Partial Discharge Measurement for Power Transformers And a Comparison to the Calibration of Electrical PD Measurement

The reliability of electrical energy networks depends on the quality and reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation may lead to catastrophic breakdowns and may cause high outage and penalty costs. To prevent these destroying events, power transformers can be tested on partial discharge (PD) activity before commissioning and monitored...

متن کامل

Partial discharge signal detection using ultra high frequency method in high voltage power equipments: a review

Partial discharge (PD) can be detected using ultra high frequency (UHF) method to increase the detection threshold and to improve the performance of on-line measurement of PD in noise environment. The PD emitted energy as electromagnetic emission, acoustic emission and ozone and nitrous oxide gases. We can use this emitted energy to detected PD signal. The best method to detect PD in gas insula...

متن کامل

Improved Bagging Algorithm for Pattern Recognition in UHF Signals of Partial Discharges

This paper presents an Improved Bagging Algorithm (IBA) to recognize ultra-high-frequency (UHF) signals of partial discharges (PDs). This approach establishes the sample information entropy for each sample and the re-sampling process of the traditional Bagging algorithm is optimized. Four typical discharge models were designed in the laboratory to simulate the internal insulation faults of powe...

متن کامل

Design of a New Built-in UHF Multi-Frequency Antenna Sensor for Partial Discharge Detection in High-Voltage Switchgears

In this study a new built-in ultrahigh frequency (UHF) antenna sensor was designed and applied in a high-voltage switchgear for partial discharge (PD) detection. The casing of the switchgear was initially used as the ground plane of the antenna sensor, which integrated the sensor into the high-voltage switchgear. The Koch snowflake patch was adopted as the radiation patch of the antenna to over...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014