Mechanical properties of a cemented porous implant interface
نویسندگان
چکیده
BACKGROUND Revision arthroplasty often requires anchoring of prostheses to poor-quality or deficient bone stock. Recently, newer porous materials have been introduced onto the market as additional, and perhaps better, treatment options for revision arthroplasty. To date, there is no information on how these porous metals interface with bone cement. This is of clinical importance, since these components may require cementing to other prosthesis components and occasionally to bone. METHODS We created porous metal and bone cylinders of the same size and geometry and cemented them in a well-established standardized setting. These were then placed under tensile loading and torsional loading until failure was achieved. This permitted comparison of the porous metal/cement interface (group A) with the well-studied bone/cement interface (group B). RESULTS The group A interface was statistically significantly stronger than the group B interface, despite having significantly reduced depth of cement penetration: it showed a larger maximum tensile force (effect size 2.7), superior maximum tensile strength (effect size 2.6), greater maximum torsional force (effect size 2.2), and higher rotational stiffness (effect size 1.5). INTERPRETATION The newer porous implants showed good interface properties when cemented using medium-viscosity bone cement. The axial and rotational mechanical strength of a porous metal/cement interface appeared to be greater than the strength of the standard bone/cement interface. These results indicate that cementing of porous implants can provide great stability in situations where it is needed.
منابع مشابه
Synthesis of Porous Nanostructure NiTi Implant and Measurement of Thermomechanical Properties
Objective(s): NiTi is known as the most important material for manufacturing implants and medical devises duo to its shape memory and superelasticity properties, high energy damping, and high corrosion resistance. Methods: In this project, the possibility of producing nanostructured NiTi implant with high porosity was investigated. For reaching to the nan...
متن کاملCement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration
Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term im...
متن کاملInfluence of Rolling on Microstructure and Mechanical Properties of Bronze-Steel Explosive Welded Sheets
In this paper, the microstructure and mechanical properties of the plain carbon steel-bronze interface of explosive welding and rolling were investigated. Explosive connection was done at two stop distances and with two different thicknesses of explosive material. Rolling of the welded composite was done at both ambient and preheated temperatures of 300 °C and with a constant thickness reductio...
متن کاملInfluence of Rolling on Microstructure and Mechanical Properties of Bronze-Steel Explosive Welded Sheets
In this paper, the microstructure and mechanical properties of the plain carbon steel-bronze interface of explosive welding and rolling were investigated. Explosive connection was done at two stop distances and with two different thicknesses of explosive material. Rolling of the welded composite was done at both ambient and preheated temperatures of 300 °C and with a constant thickness reductio...
متن کاملEffects of material properties of femoral hip components on bone remodeling.
Bone loss around femoral hip stems is one of the problems threatening the long-term fixation of uncemented stems. Many believe that this phenomenon is caused by reduced stresses in the bone (stress shielding). In the present study the mechanical consequences of different femoral stem materials were investigated using adaptive bone remodeling theory in combination with the finite element method....
متن کامل