Bronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of flow pattern.
نویسندگان
چکیده
In mechanically ventilated patients the flow pattern during bronchodilator delivery by metered-dose inhaler (MDI) could be a factor that might influence the effectiveness of this therapy. In order to test this the effect of two different inspiratory flow patterns on the bronchodilation induced by beta2-agonists administered via MDI and spacer in a group of mechanically ventilated patients with chronic obstructive pulmonary disease (COPD) was examined. Eighteen mechanically ventilated patients with COPD, were prospectively randomized to receive two (n=8, protocol A) or six (n=10 protocol B) puffs salbutamol (100 microg x puff(-1)) either under pressure control (decelerating flow pattern) or under volume control (square wave flow pattern). With both modes, tidal volume and inspiratory time were identical. Salbutamol was administered via an MDI adapted to the inspiratory limb of the ventilator circuit using an aerosol cloud-enhancer spacer. After a 6-h washout, patients were crossed over to receive the same dose of salbutamol (200 or 600 microg, respectively in protocols A and B) by the alternative mode of administration. Static and dynamic airway pressures, minimum (Rint) and maximum (Rrs) inspiratory resistance and the difference between Rrs and Rint (deltaR) were measured before and at 15, 30 and 60 min after salbutamol. Independent of the dose, salbutamol caused a significant decrease in dynamic and static airway pressures, Rint and Rrs. These changes were not influenced by the inspiratory flow pattern and were evident at 15, 30 and 60 min after salbutamol. It is concluded that salbutamol delivered via metered dose inhaler and spacer device, induces significant bronchodilation in mechanically ventilated patients with chronic obstructive pulmonary disease, the magnitude of which is not affected by the inspiratory flow/time profile.
منابع مشابه
Bronchodilator therapy with metered-dose inhaler and spacer versus nebulizer in mechanically ventilated patients: comparison of magnitude and duration of response.
OBJECTIVE Four-hour comparison of the bronchodilator response of albuterol administered via metered-dose inhaler (MDI) with spacer versus small-volume nebulizer (SVN) to mechanically ventilated patients with chronic obstructive pulmonary disease (COPD). DESIGN Prospective randomized clinical trial. SETTING Medical intensive care unit in a university hospital. PATIENTS Thirteen mechanicall...
متن کاملBronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of end-inspiratory pause.
The delivery of bronchodilators with a metered-dose inhaler (MDI) and a spacer in mechanically ventilated patients has become widespread practice. However, the various ventilator settings that influence the efficacy of MDI are not well established. Application of an end-inspiratory pause (EIP) during drug delivery has been suggested as one of the factors that might increase the effectiveness of...
متن کاملInhalation therapy with metered-dose inhalers and dry powder inhalers in mechanically ventilated patients.
Pressurized metered-dose inhalers (pMDIs) are commonly employed for administering bronchodilator aerosols to mechanically ventilated patients. Although it is feasible to employ dry powder inhalers in ventilator circuits, the presence of humidity in the ventilator circuit could reduce their efficiency. A complex array of factors influence drug delivery from pMDIs during mechanical ventilation, a...
متن کاملBronchodilator delivery with metered-dose inhalers in mechanically-ventilated patients.
Metered-dose inhalers (MDIs) provide several advantages over nebulizers, including ease of administration, decreased cost, reliability of dosing, and freedom from contamination. However, this method of aerosol delivery has been considered ineffective in mechanically-ventilated patients because most of the aerosol deposits in the endotracheal tube and ventilator circuit. A smaller amount of aero...
متن کاملInhalation therapy in patients receiving mechanical ventilation: an update.
Incremental gains in understanding the influence of various factors on aerosol delivery in concert with technological advancements over the past 2 decades have fueled an ever burgeoning literature on aerosol therapy during mechanical ventilation. In-line use of pressurized metered-dose inhalers (pMDIs) and nebulizers is influenced by a host of factors, some of which are unique to ventilator-sup...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 16 2 شماره
صفحات -
تاریخ انتشار 2000