Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
نویسندگان
چکیده
OBJECTIVES To compare image quality on computed tomographic (CT) images acquired with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) techniques in CT kidney/ureter/bladder (KUB) examination. METHODS Eighteen patients underwent standard protocol CT KUB at our institution. The same raw data were reconstructed using FBP, ASIR and MBIR. Objective [mean image noise, contrast-to-noise ratio (CNR) for kidney and mean attenuation values of subcutaneous fat] and subjective image parameters (image noise, image contrast, overall visibility of kidneys/ureters/bladder, visibility of small structures, and overall diagnostic confidence) were assessed using a scoring system from 1 (best) to 5 (worst). RESULTS Objective image measurements revealed significantly less image noise and higher CNR and the same fat attenuation values for the MBIR technique (P < 0.05). MBIR scored best in all the subjective image parameters (P < 0.001) with averages ranging between 2.05-2.73 for MBIR, 2.95-3.10 for ASIR and 3.08-3.31 for FBP. No significant difference was observed between FBP and ASIR (P > 0.05), while there was a significant difference between ASIR vs. MBIR (P < 0.05). The mean effective dose was 3 mSv. CONCLUSION MBIR shows superior reduction in noise and improved image quality (both objective and subjective analysis) compared with ASIR and FBP CT KUB examinations. MAIN MESSAGES • There are many reconstruction options in CT. • Novel model-based iterative reconstruction (MBIR) showed the least noise and optimal image quality. • For CT of the kidneys/ureters/bladder, MBIR should be utilised, if available. • Further studies to reduce the dose while maintaining image quality should be pursued.
منابع مشابه
Fast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملComparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملComparisons of Hounsfield Unit Linearity between Images Reconstructed using an Adaptive Iterative Dose Reduction (AIDR) and a Filter Back-Projection (FBP) Techniques
Background: The HU linearity is an essential parameter in a quantitative imaging and the treatment planning systems of radiotherapy. Objective: This study aims to evaluate the linearity of Hounsfield unit (HU) in applying the adaptive iterative dose reduction (AIDR) on CT scanner and its comparison to the filtered back-projection (FBP).Material and Methods: In this experimental phan...
متن کاملPatient dose and image quality in low-dose abdominal CT: a comparison between iterative reconstruction and filtered back projection.
BACKGROUND In computed tomography (CT), there is increasing concern for potential CT radiation hazards. Several raw-data-based iterative reconstruction techniques attempt to facilitate low-dose imaging without compromising image quality, which raises the question whether these techniques may allow further dose reduction. PURPOSE To compare image quality of iterative reconstruction and filtere...
متن کاملComparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography: Erratum
The purpose of this study was to compare the image noise-reducing abilities of iterative model reconstruction (IMR) with those of traditional filtered back projection (FBP) and statistical iterative reconstruction (IR) in abdominal computed tomography (CT) imagesThis institutional review board-approved retrospective study enrolled 103 patients; informed consent was waived. Urinary bladder (n = ...