NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes.
نویسندگان
چکیده
UNLABELLED The National Electrical Manufacturers Association (NEMA) NU 2-2001 performance measurements were conducted on the Discovery RX, a whole-body PET/CT system under development by GE Healthcare. The PET scanner uses 4.2 x 6.3 x 30 mm lutetium yttrium orthosilicate (LYSO) crystals grouped in 9 x 6 blocks. There are 24 rings with 630 crystals per ring and the ring diameter is 88.6 cm. The transaxial and axial fields of view are 70.0 and 15.7 cm, respectively. The scanner has retractable septa and can operate in both 2-dimensional (2D) and 3-dimensional (3D) modes. 2D acquisitions use ring differences of +/-4 for direct and +/-5 for cross slices; 3D acquisitions use a ring difference of 23. The coincident window width is 6.5 ns and the energy window is 425-650 keV. Other than the detectors, the system uses the same hardware and software as a Discovery ST. The CT scanner is a 16-slice LightSpeed; the performance characteristics of the CT component are not included herein. METHODS Performance measurements of sensitivity, spatial resolution, image quality, scatter fraction and counting rate performance, and image quality were obtained using NEMA methodology. RESULTS The system sensitivity in 2D and 3D was measured as 1.7 cps/kBq and 7.3 cps/kBq, respectively. The transaxial resolution for 2D (3D) was 5.1 mm full width at half maximum (FWHM) (5.0 mm) at 1 cm from gantry center and the radial and tangential resolutions were 5.9 mm (5.9 mm) and 5.1 mm (5.2 mm) at 10 cm, respectively. The axial resolution for 2D (3D) was 4.8 mm FWHM (5.8 mm) and 6.3 mm (6.5 mm) at 1 cm and 10 cm from gantry center, respectively. The scatter fraction was 13.1% and 31.8% in 2D and 3D. The peak noise equivalent count rate (NECR) was 155 kcps at 92.1 kBq/mL in 2D and 117.7 kcps at 21.7 kBq/mL in 3D for a noise-free estimation of randoms. The contrast of the 22, 17, 13, and 10 mm hot spheres in the image quality phantom in 2D (3D) were 74.6% (72.4%), 56.7% (59.5%), 46.2% (44.6%), and 17.9% (18.0%), respectively. CONCLUSION The Discovery RX is a scanner that possesses high NECR, low scatter fraction, and good spatial resolution characteristics.
منابع مشابه
Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE
Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...
متن کاملPET performance measurements for an LSO-based combined PET/CT scanner using the National Electrical Manufacturers Association NU 2-2001 standard.
UNLABELLED Results of performance measurements for a lutetium oxyorthosilicate (LSO)-based PET/CT scanner using new National Electrical Manufacturers Association (NEMA) NU 2-2001 standards are reported. METHODS Performance measurements following the NU 2-2001 standards were performed on an LSO-based PET/CT scanner. In addition, issues associated with the application of the NEMA standard to LS...
متن کاملAn overview of clinical PET/CT
This article is intended to provide an overview of various aspects of clinical PET/CT. These include discussions of: (i) Important areas of clinical application; (ii) Opportunities in clinical research; (iii) Scanner and operating-mode considerations (e.g. BGO vs. LSO, LYSO or GSO scanners, 2D vs. 3D imaging). (iv) Study-specific considerations (e.g. patient preparation and positioning is...
متن کاملPerformance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the National Electrical Manufacturers Association NU 2-2001 standard.
UNLABELLED This article reports the results of performance measurements obtained for the lutetium oxyorthosilicate (LSO)-based whole-body PET/CT scanner Biograph 16 HI-REZ with the National Electrical Manufacturers Association (NEMA) NU 2-2001 standard. The Biograph 16 HI-REZ combines a multislice (16-slice) spiral CT scanner with a PET scanner composed of 24.336 LSO crystals arranged in 39 rin...
متن کاملPerformance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using GATE
Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner performances on an objective ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 47 12 شماره
صفحات -
تاریخ انتشار 2006