Ion yield improvement for static secondary ion mass spectrometry by use of polyatomic primary ions.

نویسندگان

  • Roel De Mondt
  • Luc Van Vaeck
  • Andreas Heile
  • Heinrich F Arlinghaus
  • Nicolas Nieuwjaer
  • Arnaud Delcorte
  • Patrick Bertrand
  • Jens Lenaerts
  • Frank Vangaever
چکیده

Static secondary ion mass spectrometry (S-SIMS) is one of the potentially most powerful and versatile tools for the analysis of surface components at the monolayer level. Current improvements in detection limit (LOD) and molecular specificity rely on the optimisation of the desorption-ionisation (DI) process. As an alternative to monoatomic projectiles, polyatomic primary ion (P.I.) bombardment increases ion yields non-linearly. Common P.I. sources are Ga+ (liquid metal ion gun (LMIG), SF5+ (electron ionisation) and the newer Au(n)+, Bi(n)q+ (both LMIG) and C60+ (electron ionisation) sources. In this study the ion yield improvement obtained by using the newly developed ion sources is assessed. Two dyes (zwitterionic and/or thermolabile polar functionalities on a largely conjugated backbone) were analysed as a thin layer using Ga+, SF5+, C60+, Bi+, Bi3(2+) and Bi5(2+) projectiles under static conditions. The study aims at evaluating the improvement in LOD, useful and characteristic yield and molecular specificity. The corrected total ion count values for the different P.I. sources are compared for different instruments to obtain a rough estimate of the improvements. Furthermore, tentative ionisation and fragmentation schemes are provided to describe the generation of radical and adduct ions. Characteristic ion yields are discussed for the different P.I. sources. An overview of the general appearances of the mass spectra obtained with the different P.I. sources is given to stress the major improvement provided by polyatomic P.I.s in yielding information at higher m/z values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lipid specific molecular ion emission as a function of the primary ion characteristics in TOF-SIMS.

In the present work, the emission characteristics of lipids as a function of the primary ion cluster size and energy were studied using time-of-flight secondary ion mass spectrometry (TOF-SIMS). Characteristic fragmentation patterns for common lipids are described, and changes in secondary ion (SI) yields using various primary ion beams are reported. In particular, emission characteristics were...

متن کامل

Mass spectrometric imaging of brain tissue by time‐of‐flight secondary ion mass spectrometry – How do polyatomic primary beams C60 +, Ar2000 +, water‐doped Ar2000 + and (H2O)6000 + compare?

RATIONALE To discover the degree to which water-containing cluster beams increase secondary ion yield and reduce the matrix effect in time-of-flight secondary ion mass spectrometry (TOF-SIMS) imaging of biological tissue. METHODS The positive SIMS ion yields from model compounds, mouse brain lipid extract and mouse brain tissue together with mouse brain images were compared using 20 keV C60(+...

متن کامل

Matrix-enhanced secondary ion mass spectrometry: The Alchemist’s solution?

Because of the requirements of large molecule characterization and high-lateral resolution SIMS imaging, the possibility of improving molecular ion yields by the use of specific sample preparation procedures has recently generated a renewed interest in the static SIMS community. In comparison with polyatomic projectiles, however, signal enhancement by a matrix might appear to some as the alchem...

متن کامل

New Cs sputter ion source with polyatomic ion beams for secondary ion mass spectrometry applications.

A simple design for a cesium sputter ion source compatible with vacuum and ion-optical systems as well as with electronics of the commercially available Cameca IMS-4f instrument is reported. This ion source has been tested with the cluster primary ions of Si(n)(-) and Cu(n)(-). Our experiments with surface characterization and depth profiling conducted to date demonstrate improvements of the an...

متن کامل

Primary ion fluence dependence in time-of-flight SIMS of self-assembled monolayer of alkyl thiol molecules on Au(1 1 1)—Discussion of static limit

The nondestructive nature of static secondary ion mass spectrometry (SIMS) in the context of studies of self-assembled monolayers (SAMs) of organic molecules has been examined by measuring the primary ion fluence dependence of secondary ion signals with two well-known SAMs, C18H37SH on Au(1 1 1) and C18H37PO3H2 on freshly cleaved mica. This SIMS analysis is challenging because the bonding natur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 2008