Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer
نویسندگان
چکیده
A bolometer detector system was developed for the high accuracy infrared spectrophotometer at the National Institute of Standards and Technology to provide maximum sensitivity, spatial uniformity, and linearity of response covering the entire infrared spectral range. The spatial response variation was measured to be within 0.1 %. The linearity of the detector output was measured over three decades of input power. After applying a simple correction procedure, the detector output was found to deviate less than 0.2 % from linear behavior over this range. The noise equivalent power (NEP) of the bolometer system was 6 × 10-12 [Formula: see text] at the frequency of 80 Hz. The detector output 3 dB roll-off frequency was 200 Hz. The detector output was stable to within ± 0.05 % over a 15 min period. These results demonstrate that the bolometer detector system will serve as an excellent detector for the high accuracy infrared spectrophotometer.
منابع مشابه
Design for the COBE1 Far Infrared Absolute Spectrophotometer (FIRAS)
The Far InfraRed Absolute Spectrophotometer (FIRAS) was built to measure the spectrum of diiuse emission from 1 to 100 cm ?1 , with particular attention to possible diierences between the spectrum of the cosmic microwave background radiation (CMBR) and a blackbody spectrum as small as 0.1% of the peak of the CMBR spectrum. The FIRAS has diierential inputs and outputs, a full beam external calib...
متن کاملA far-infrared Fourier transform spectrometer with an antenna-coupled niobium bolometer
We have designed and constructed a custom far-infrared Fourier transform spectrometer using an antenna-coupled bolometer as a detector. The active element of the detector is a superconducting niobium microbridge, and the far-infrared signal is coupled to the microbridge via a planar antenna mounted on a hyperhemispherical silicon lens. The spectrometer uses a broadband blackbody source with fre...
متن کاملInvestigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code
Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...
متن کاملNIST High Accuracy Reference Reflectometer-Spectrophotometer
A new reflectometer-spectrophotometer has been designed and constructed using state-of-the-art technology to enhance optical properties of materials measurements over the ultraviolet, visible, and near-infrared (UV-Vis-NIR) wavelength range (200 nm to 2500 nm). The instrument, Spectral Tri-function Automated Reference Reflectometer (STARR), is capable of measuring specular and diffuse reflectan...
متن کاملRealization of the National Institute of Standards and Technology detector-based spectral irradiance scale.
A detector-based spectral irradiance scale has been realized at the National Institute of Standards and Technology (NIST). Unlike the previous NIST spectral irradiance scales, the new scale is generated with filter radiometers calibrated for absolute spectral power responsivity traceable to the NIST high-accuracy cryogenic radiometer instead of with the gold freezing-point blackbody. The calibr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 103 شماره
صفحات -
تاریخ انتشار 1998