Simultaneous Multi-slice MRI Reconstruction using LORAKS
نویسندگان
چکیده
Introduction The combination of simultaneous multi-slice (SMS) acquisition with parallel imaging enables highly-accelerated MRI experiments [1,2]. However, most existing methods use highly structured k-space sampling, and require either prior knowledge of the coil sensitivity maps [1,2] or autocalibration data [3]. In this work, we propose a constrained reconstruction framework that works with traditional sampling schemes, but is flexible enough to also be used with calibrationless unstructured sampling patterns without any prior sensitivity information. The approach is also flexible enough that it can be used with single-channel data and/or random SMS encoding [4,5]. Our proposed approach specifically uses low-rank matrix modeling of local k-space neighborhoods (LORAKS) [6,7], a recent calibrationless MR image reconstruction framework that enables new kspace sampling trajectories for both singleand multi-channel data. Combining SMS with LORAKS leads to a framework we call SMS-LORAKS. Methods Data acquisition: Similar to existing SMS methods [1-3,5], we assume that multiple slices are excited simultaneously and Fourier encoded simultaneously, with measurements acquired using a phased array coil. The spatially-varying coil sensitivities provide information that can be used to help separate the signal from different slices. To make the separation of different slices even easier, spatially-selective RF pulses and/or imaging gradients can be used to change the phase relationships between the different slices for each individual phase encoding step (we refer to this as “slice encoding”). The slice encoding can either be performed in a structured way (as in Hadamard encoding) [1-3] or in a random way [4,5]. The information provided by the combination of coil sensitivities and slice encoding leads to data redundancies, which enables sub-sampling of k-space. Reconstruction: We use the LORAKS framework [6,7] to reconstruct sub-sampled SMS data without coil sensitivity information and without autocalibration data. LORAKS is based on the assumptions that MR images frequently have limited spatial support and slowly-varying spatial image phase. These constraints result in linear dependence relationships that allow missing k-space data to be linearly predicted from neighboring k-space samples and/or k-space samples on the opposite half of k-space. In the absence of prior information about the linear dependencies, the relationships between neighboring k-space points can be imposed implicitly using low rank matrices. Specifically, linear dependence relationships imply that single-channel k-space data can be rearranged into structured matrices that must have low rank, and matrices with even better rank characteristics can be constructed in the presence of parallel imaging data [7]. The low-rank matrix structure can be enforced using regularization [6,7]. SMSLORAKS reconstruction is achieved by minimizing the functional ∑ ||∑ l l||l l λ ∑ λ ∑ , where l is the unknown (to be estimated) fully-sampled k-space data from the th slice and the lth coil; l is the measured data from the lth coil; the matrices describe the slice encoding, Fourier encoding, and Fourier sub-sampling operations for the th slice; and are structured low-rank matrices formed from the k-space data from the th slice (i.e., formed from the set of vectors , , ... , as described in the P-LORAKS method [7]); and ⋅ is a regularization functional that encourages low-rank matrix structure. The matrix is used to model support constraints for the th slice, while the matrix is used to model phase constraints for the th slice. Note that the individual slices are being regularized independently, as we are not making any assumptions about inter-slice correlations. On the other hand, the reconstruction of the individual slices is coupled through the data fidelity terms, since each measured datapoint represents a combination of information from each of the different slices. The SMS-LORAKS optimization problem is solved using a majorize-minimize algorithm [6,7]. Results Due to space constraints, we only show a few results. Fig. 1 shows the results of applying SMS-LORAKS to retrospectively undersampled 12-channel 2-slice data with 3× acceleration, using a random calibrationless partial-Fourier k-space sampling scheme. SMS-LORAKS performs quite well, and we are unaware of any other method that could successfully reconstruct this kind of measured data. Note that the use of partialFourier undersampling allows the sampling density to be greater than it would have been if the same number of phase encodings were distributed over the full k-space grid. Joint total-variation reconstruction [8] is not nearly as successful. We also observe that there is not much difference in reconstruction quality between sub-sampled Hadamard slice encoding and sub-sampled random slice encoding. Other results demonstrate that singlechannel SMS-LORAKS is also feasible with up to 5/8ths sub-sampling (data not shown).
منابع مشابه
P-LORAKS: Low-rank modeling of local k-space neighborhoods with parallel imaging data.
PURPOSE To propose and evaluate P-LORAKS a new calibrationless parallel imaging reconstruction framework. THEORY AND METHODS LORAKS is a flexible and powerful framework that was recently proposed for constrained MRI reconstruction. LORAKS was based on the observation that certain matrices constructed from fully sampled k-space data should have low rank whenever the image has limited support o...
متن کاملImproving parallel imaging by jointly reconstructing multi-contrast data.
PURPOSE To develop parallel imaging techniques that simultaneously exploit coil sensitivity encoding, image phase prior information, similarities across multiple images, and complementary k-space sampling for highly accelerated data acquisition. METHODS We introduce joint virtual coil (JVC)-generalized autocalibrating partially parallel acquisitions (GRAPPA) to jointly reconstruct data acquir...
متن کاملLow-Rank Modeling of Local $k$-Space Neighborhoods (LORAKS) for Constrained MRI
Recent theoretical results on low-rank matrix reconstruction have inspired significant interest in low-rank modeling of MRI images. Existing approaches have focused on higher-dimensional scenarios with data available from multiple channels, timepoints, or image contrasts. The present work demonstrates that single-channel, single-contrast, single-timepoint k-space data can also be mapped to low-...
متن کاملAc-loraks: Autocalibrated Low-rank Modeling of Local K-space Neighborhoods
Introduction: Low-rank modeling of local k-space neighborhoods (LORAKS) is a recent constrained MRI framework that can enable accurate image reconstruction from sparselyand unconventionally-sampled k-space data [1,2]. Specifically, Ref. [1] showed that the k-space data for MR images that have limited spatial support or slowly-varying image phase can be mapped into structured low-rank matrices, ...
متن کاملImproving diffusion MRI using simultaneous multi-slice echo planar imaging
In diffusion MRI, simultaneous multi-slice single-shot EPI acquisitions have the potential to increase the number of diffusion directions obtained per unit time, allowing more diffusion encoding in high angular resolution diffusion imaging (HARDI) acquisitions. Nonetheless, unaliasing simultaneously acquired, closely spaced slices with parallel imaging methods can be difficult, leading to high ...
متن کامل