The influence of surface topography on wear debris generation at the cement/bone interface under cyclic loading.

نویسندگان

  • Kirk A Stoffel
  • Dongliang T Yang
  • Dwayne Arola
چکیده

The long-term success of a total joint replacement can be undermined by loosening of the implant, generation of wear debris or a combination of both factors. In the present study the influence of the surface morphologies of the bone and cement mantle on loosening of cemented total joint replacements (THJRs) and development of wear debris were studied. Model cemented THJR specimens were prepared in which the femoral canal was textured using specific cutting tools. The specimens were subjected to cyclic loads inducing pure shear fatigue of the cement/bone interface. Changes in both the femoral canal and cement mantle resulting from fatigue were quantified in terms of the surface topography and the volume of wear debris. Loosening occurred with cyclic loading due to degradation of the cement and bone and resulted in the development of cement and bone particles. There was no correlation between the fatigue strength of the interfaces and the volume of wear debris. In general, the change in surface topography of the cement mantle with fatigue decreased with increasing volume of cement interdigitation. Femoral canal surfaces with symmetric profile height distribution (i.e., Gaussian surfaces) resulted in the lowest volume of generated debris.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Generation of Fretting Wear Debris at the Stem– Cement Interface in Total Hip Replacment

Fretting wear debris generated at the stem–cement interface has nowadays been considered to play an important role in the overall failure of cemented total hip replacement (THR). Those wear debris within a certain size range would transport along bone cement deficiencies to bone tissue, resulting in a significant bone resorption and subsequent aseptic loosening of the femoral component, which i...

متن کامل

Reproduction of fretting wear at the stem-cement interface in total hip replacement.

The stem-cement interface experiences fretting wear in vivo due to low-amplitude oscillatory micromotion under physiological loading, as a consequence it is considered to play an important part in the overall wear of cemented total hip replacement. Despite its potential significance, in-vitro simulation to reproduce fretting wear has seldom been attempted and even then with only limited success...

متن کامل

In vitro influence of stem surface finish and mantle conformity on pressure generation in cemented hip arthroplasty

BACKGROUND AND PURPOSE Under physiological loads, debonded cemented femoral stems have been shown to move within their cement mantle and generate a fluid pump that may facilitate peri-prosthetic osteolysis by pressurizing fluid and circulating wear debris. The long-term physiological loading of rough and polished tapered stems in vitro has shown differences in performance, with greater interfac...

متن کامل

Bone-Implant Interface Biology ―― Foreign Body Reaction and Periprosthetic Osteolysis in Artificial Hip Joints――

Aseptic loosening and periprosthetic osteolysis are major problems in artificial hip joint surgery,for which a solution has yet to be found. Biological host response to wear debris combined with cyclic mechanical loading onto the bone bed around hip prosthetic implants has been considered as mechanism responsible for implant-mediated periprosthetic osteolysis. Any type of artificial joint glidi...

متن کامل

Fatigue of the cement/bone interface: the surface texture of bone and loosening.

Loosening is recognized as one of the primary sources of total hip replacement (THR) failure. In this study the influence of the bone surface texture on loosening of the cement/bone interface was studied. Model cemented hip replacements were prepared and subjected to cyclic loads that induced pure shear fatigue of the cement/bone interface. The femoral canals were textured with the use of speci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of materials science. Materials in medicine

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 2008