Synchronous self-elimination of autocorrelation interference in Fourier-domain optical coherence tomography.

نویسندگان

  • Jun Ai
  • Lihong V Wang
چکیده

We have developed a new algorithm and configuration for self-eliminating the autocorrelation of the object wave in Fourier-domain optical coherence tomography. A self-interferogram of the object wave is acquired synchronously with the standard interferogram of the recombined object and reference waves. The former is then subtracted from the latter after Fourier transformation. The algorithm is validated by numerical simulation and by experimental measurement of a U.S. Air Force target and a feline eye.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اندازه‌گیری همزمان ضریب شکست و ضخامت فیزیکی دستگاه‌های چندلایه‌ای با استفاده از نتایج مقطع‌نگاری همدوسی اپتیکی در فضای فوریه

In fourier domain optical coherence tomography, we can measure the optical thickness ( refractive index n times thickness d), to obtain the retinal layers in order to diagnose many disorders. In this work, we introduce a new method for measurement of refractive index and physical thickness of multiple layers simultaneously by Fourier domain optical coherence tomography, without additional infor...

متن کامل

Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator.

A novel swept-laser-based Fourier-domain optical coherence tomography system using an electro-optic phase modulator was demonstrated. The imaging range was doubled by cancellation of the mirror image. The elimination of low-frequency noises resulting from dc and autocorrelation terms increased the sensitivity by 20 dB.

متن کامل

Simultaneous acquisition of the real and imaginary components in Fourier domain optical coherence tomography using harmonic detection

Fourier domain optical coherence tomography (FD-OCT) is an interferometric imaging technique that allows imaging to depths of a few mm in scattering biological tissues with high resolution of the order of 1-10 μm. However, the usefulness of FD-OCT is limited by background and autocorrelation interference terms that reduce the sensitivity and by phase ambiguity that halves the useful imaging dep...

متن کامل

Demonstration of complex-conjugate-resolved harmonic Fourier-domain optical coherence tomography imaging of biological samples.

Complex-conjugate-resolved Fourier-domain optical coherence tomography, where the quadrature components of the interferogram are obtained by simultaneous acquisition of the first and second harmonics of the phase-modulated interferogram, is applied to multisurface test targets and biological samples. The method provides efficient suppression of the complex-conjugate, dc, and autocorrelation art...

متن کامل

Autocorrelation artifacts in optical coherence tomography and interferometric synthetic aperture microscopy.

Interferometric synthetic aperture microscopy processing of optical coherence tomography data has been shown to allow computational focusing of en face planes that have traditionally been regarded as out of focus. It is shown that this focusing of the image also produces a defocusing effect in autocorrelation artifacts resulting from Fourier-domain data collection. This effect is verified exper...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 30 21  شماره 

صفحات  -

تاریخ انتشار 2005