Polythiophene nanofilms for sensitive fluorescence detection of viruses in drinking water.
نویسندگان
چکیده
Molecular imprints of the tobacco necrosis virus (TNV) have been formed within polythiophene nanofilms with an approximate thickness of 200nm. These films have been electrochemically deposited onto conducting Au surfaces. Upon rebinding, the TNV-polythiophene complex changes the fluorescence intensity of the nanofilm. The fluorescence intensity at 410nm was observed to be proportional to the concentration of viruses in the range of 0.1-10ngL(-1) (0.15-15pg) with the lower calculated detection limit of 2.29ngL(-1) (3.4pg). The intensity of the fluorescence emission is not affected by the thickness of the polythiophene film and the nature of TNV specific binding sites. Kinetic data analyses showed that the nanofilm responds to TNV within 2min; and cross-selectivity studies with tobacco mosaic virus (TMV) showed an excellent specificity for the targeted TNV. These binding experiments demonstrate the potential of fluorescence emission for the specific, label free and rapid detection of viruses using nanofilm sensors. Taking into account the lower limit of detection, the fluorescence sensing reported here is reliable, simple to perform, rapid, cost-effective and offers a sensitive analytical method for virus detection in water resources.
منابع مشابه
Rapid detection of the most important pathogenic microorganisms in water and Food by (Chromogenic media)
Abstract Background and Objectives: Chromogenic media are the newest methods applied for rapid detection of pathogenic microorganisms in drinking water and food from 1998-2008. These Specific media contained the compounds acting as a substrate for microbial enzymes and, according to the type of enzyme, produce specific color. The aim of this study was to introduce the chromogenic media as a pow...
متن کاملA Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملA Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملGraphene Oxide-terpyridine Conjugate: A Highly Selective Colorimetric and Sensitive Fluorescence Nano-chemosensor for Fe2+ in Aqueous Media
A graphene oxide-terpyridine conjugate (GOTC) based colorimetric and fluorescent nano-chemosensor was synthesized. It showed high selectivity and sensitivity for Fe2+ and Fe3+ ions in neutral aqueous solution over other metal ions such as Li+, Na+, Ba2+, Ca2+, Al3+, Cd2+, Co2+, Cu2+, Hg2+, Mn...
متن کاملGraphene oxide supported gold nanoclusters for the sensitive and selective detection of nitrite ions.
The research progress on the selective and sensitive fluorescent detection of nitrite anions has greatly relied on the development of new fluorescent materials. Herein, a novel nanohybrid exhibiting dual emissions in blue and red wavelength ranges is fabricated for the rapid, on-site, and sensitive detection of nitrite anions. Such a nanohybrid system consists of graphene oxide (GO-C6NH2) and g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biosensors & bioelectronics
دوره 82 شماره
صفحات -
تاریخ انتشار 2016