Curvature analyses of the corneal front and back surface.
نویسندگان
چکیده
In 25 eyes, age range 60-80 years, in purpose of preoperative treatment prior to cataract surgery, measurements of the radius of curvature as well as main meridians of the anterior and posterior corneal surfaces were performed. Average value of the curvature of the anterior corneal surface (R1) was R1 = 7.84 mm, while posterior radius (R2) was 6.4 mm. Main meridian of the anterior corneal surface was in 70% in plus value (+), while postrerior main meridian was always in minus value. It is very important to highlight that main corneal meridians R1 and R2 always cross outside the 90 degrees angle. That is why the combination of the calculation based on the two main meridians superposition (overrefraction) as a form of crossed cylinders has to be calculated (Astigmatismus directus seu obliquus decusatus) using special formula. One of that kind of formulas is Thompson's. Authors want to emphasise the importance of the optical calculation of the posterior corneal surface in the refractive surgery.
منابع مشابه
Influence of front row burden on fragmentation, Muckpile shape, Excavator cycle time, and back break in surface Limestone Mines
Front row burden is one of the key parameter to improve the bench blasting results. Improper design of the front row burden can create nuisances in the form of ground vibration, flyrock, back break or it may responsible for breakage of improper fragment size from the rockmass. Therefore, front row burden need to be optimised on the basis of proper scientific assessment. It has been proved that ...
متن کاملبررسی اثر قطره هوماتروپین 2% بر روی توپوگرافی قرنیه
ABSTRACT The purpose of this study was the evaluation of cycloplegic effect of homatropine 2% on central corneal curvature and power. 43 volunteers who participated in the study were examined. Thirty-nine of them (28 men and 11 women) which had normal eyes with visual acuity of 20/20 and a mean age of 29.6 ± 6.7 years were selected. Then corneal topography was performed on both eyes. After per...
متن کاملFellow eye comparison of corneal thickness and curvature in descemet membrane endothelial keratoplasty and descemet stripping automated endothelial keratoplasty.
PURPOSE To compare posterior corneal curvature in the fellow eye of the same patients after Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK). METHODS This retrospective, case series comparative study included consecutive patients who underwent DSAEK in one eye and DMEK in the fellow eye. Each eye underwent corneal evaluation w...
متن کاملPentacam HR criteria for curvature change in keratoconus and postoperative LASIK ectasia.
PURPOSE To determine criteria for keratoconus or postoperative LASIK ectasia progression or improvement based on Pentacam HR (Oculus Optikgeräte GmbH) measured steepest corneal curvature. METHODS Sixty-one eyes from 41 patients with keratoconus or postoperative LASIK ectasia were evaluated. Each eye was measured 5 times with the Pentacam HR during the same clinic visit and the random measurem...
متن کاملFuture challenges to aberration-free ablative procedures.
ne of the exciting new research areas in laser refractive surgery is the development of sophisticated devices to measure the wave-front of the optical system of the entire eye, the various implementations of which are described in this proceedings. The ability to objectively measure performance of the eye, as opposed to simple corneal shape, is critical to " customizing " ablation algorithms an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Collegium antropologicum
دوره 37 Suppl 1 شماره
صفحات -
تاریخ انتشار 2013