ULV droplet spectra: comparative analysis of six droplet collection methods.
نویسندگان
چکیده
Three distances (1.2, 3.0 and 7.6 m) and 4 methods (complete diagonal swing, impinger, top diagonal swing and vertical swing) were compared in analyzing the droplet spectra of electrically generated ULV aerosol clouds. There were no significant differences among the 4 methods and no interaction between method and distance. However, when compared over distance, the percent variability indicated the complete diagonal swing provided the most consistent results. Two additional methods (pendulum and settling chamber) were compared with the original 4 methods at 1.2 m only. At this distance, there was no significant difference among the 6 methods.
منابع مشابه
Comparative Analysis of a Single Fuel Droplet Evaporation
In this research, the results of comparative analysis of a single fuel droplet evaporation models are presented. Three well-known evaporation models including Spalding, Borman-Johnson and Abramzon-Sirignano models are analyzed using Computational Fluid Dynamic (CFD). The original Spalding model is extended to consider the effects of the Stefan flow, unsteady vaporization, and variable propertie...
متن کاملA critical review of ultralow-volume aerosols of insecticide applied with vehicle-mounted generators for adult mosquito control.
This review of ultralow-volume (ULV) ground aerosols for adult mosquito control includes discussion on application volume, aerosol generators, droplet size, meteorology, swath, dispersal speed, assay methods, insecticide efficacy, and nontarget effects. It summarizes the efficacy of ULV insecticidal aerosols against many important pest and disease-bearing species of mosquitoes in a wide range o...
متن کاملA droplet collection device and support system for ultra-low-volume adulticide trials.
A supporting stand to suspend rotating impactors and mosquito cages is a requirement for field tests during pesticide efficacy trials. We present schematics for a collection device and associated support system for sampling droplets of ultra-low-volume (ULV) sprays during mosquito adulticide applications. This system offers the advantages of cost efficiency, increased ease of deployment, off-se...
متن کاملDroplet Characteristics and Near Nozzle Dispersion of Cold and Thermal Fog
In an effort to improve application methods for controlling sand flies in desert environments, a hand-held ultra-low volume (ULV) aerosol generator, a truck-mounted ULV aerosol generator, and a hand-held thermal fogger were evaluated. The velocity and temperature of the air and characteristics of droplets generated by these aerosol generators were measured at various distances from the nozzle. ...
متن کاملSteady State Analysis of Nanofuel Droplet Evaporation
The potential for nanofuels as one of the clean sources of energy on account of its enhanced combustion performance coupled with low emissions has been established. Considering the importance of the fuel evaporation phase in the entire combustion process, this work presents an attempt at applying the steady state analysis equations to nanofuel experimental data obtained from the li...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Mosquito Control Association
دوره 6 4 شماره
صفحات -
تاریخ انتشار 1990