Deflation failure of Accura Balloon In Left Atrium During Balloon Mitral Valvuloplasty
نویسندگان
چکیده
Currently Percutaneous Balloon Mitral Valvuloplasty has established itself as a standard treatment for patients with severe mitral stenosis. A patient with severe mitral stenosis was posted for the above procedure. After dilatation of mitral valvular apparatus the Accura balloon failed to deflate on repeated aspirations, probably due to rupture of internal lumen. Finally, a guide wire was passed through the injection port which recanalized the lumen and dye was slowly aspirated after diluting with saline. INTRODUCTION Almost all mitral stenosis (MS) is rheumatic in etiology. 1 PBMV using the Accura or Inoue balloon catheter is now an established mode of therapy for suitable cases of mitral stenosis with a success rate of more than 90% in various studies. Balloon valvuloplasty occasionally is associated with complications, including death in 0 to 1%, moderate or severe valvular regurgitation in 2 to 3%, and systemic embolization in 1 to 3%. We hereby report an unusual complication of deflation failure of Accura balloon (Vascular Concepts Limited, China) after dilatation of the mitral valve inside the left atrium.
منابع مشابه
SHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY
BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...
متن کاملImmediate Results of Percutaneous Mitral Balloon Valvuloplasty in Patients with Mitral Stenosis
Introduction: Mitral stenosis is a prevalent valvular disease in developing countries. Percutaneous mitral balloon valvuloplasty (PMBV) is the gold standard treatment. The main objective of this study was to assess the initial results of PMBV in patients with mitral stenosis during 16 years (2002-2018) in Mashhad, Iran. Materials and Methods: From April 2002 to March 2018, 770 patients underwen...
متن کاملNew technique for challenging cases of percutaneous balloon mitral valvuloplasty: The venoarterial looping
Mitral stenosis (MS) is generally the sequel of rheumatic carditis occurring in childhood (1). MS is particularly observed in developing countries (1, 2). Untreated patients can develop irreversible right ventricular failure (1, 2). Since its introduction by Inoue, percutaneous mitral balloon valvuloplasty (PMBV) is considered the leading and effective treatment option for symptomatic moderate ...
متن کاملLeft atrium reverse remodeling in patients with mitral valve stenosis after percutaneous valvuloplasty: a 2- and 3-dimensional echocardiographic study.
INTRODUCTION AND OBJECTIVES The left atrium is clinically relevant in patients with mitral valve stenosis. The objective of this study was to analyze the effects of percutaneous balloon valvuloplasty on left atrium volumes and the left atrium emptying fraction in symptomatic mitral valve stenosis patients using 2-dimensional and real-time 3 -dimensional transthoracic echocardiography. METHODS...
متن کاملPercutaneous mitral balloon valvuloplasty. Difficult mitral valve crossing
Introduction Percutaneous mitral balloon valvuloplasty (PMBV) is the treatment of choice for significant mitral stenosis (MS). The inability to cross the mitral valve accounts for a non-negligible rate of unsuccessful PMBV. This may be caused by unfavorable septal puncture or extensive enlargement of the left atrium (LA), both resulting in insufficient support. Advanced valvular and subvalvular...
متن کامل