Precise fine-structure and hyperfine-structure measurements in Rb

نویسندگان

  • Ayan Banerjee
  • Dipankar Das
  • Vasant Natarajan
چکیده

We demonstrate a new technique for measuring the absolute frequencies of atomic transitions. The technique uses a ring-cavity resonator whose length is calibrated using a reference laser locked to the D2 line in Rb. The frequency of this line is known to be 384 230 484.468(10) MHz. Using a second laser locked to the D1 line of Rb, we measure the frequencies of various hyperfine transitions in the D1 and D2 lines with a precision of 30 kHz. We obtain the following values: 120.687(17) MHz and 406.520(25) MHz for the 5P1/2 hyperfine constant A in Rb and Rb; 377 107 385.623(50) MHz and 377 107 463.209(50) MHz for the D1 line in Rb and Rb; and 384 230 406.528(50) MHz for the D2 line in Rb. This yields the fine-structure interval and the isotope shifts. The precision obtained is a significant improvement over previous measurements. Typeset using REVTEX Electronic address: [email protected]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct measurement of the fine-structure interval in alkali atoms using diode lasers

We demonstrate a technique for directly measuring the fine-structure interval in alkali atoms using two frequency-stabilized diode lasers. Each laser has a linewidth of order 1 MHz and precise tunability: one laser is tuned to a hyperfine transition in theD1 line, and the other laser to a hyperfine transition in the D2 line. The outputs of the lasers are fed into a scanning Michelson interferom...

متن کامل

Precise frequency measurements of atomic transitions using a Rb-stabilized resonator

We demonstrate a technique for frequency measurements of atomic transitions with a precision of 30 kHz. The frequency is measured using a ring-cavity resonator whose length is calibrated against a reference laser locked to the D2 line of Rb, the frequency of which is known to 10 kHz. We have used this to measure the hyperfine structure in the 5P3/2 state of Rb. We obtain precise values for the ...

متن کامل

Precise measurements of UV atomic lines: Hyperfine structure and isotope shifts in the 398.8 nm line of Yb

– We demonstrate a technique for frequency measurements of UV transitions with sub-MHz precision. The frequency is measured using a ring-cavity resonator whose length is calibrated against a reference laser locked to the D2 line of Rb. We have used this to measure the 398.8 nm 1S0 ↔ P 1 line of atomic Yb. We report isotope shifts of all the seven stable isotopes, including the rarest isotope Yb...

متن کامل

Precise frequency measurements of the D - lines and fine - structure interval in K

We use a diode laser locked to a Rb transition as the frequency reference along with a scanning Michelson interferometer to make precise measurements on the D1 and D2 lines of potassium. The Rb reference frequency is known with sub-MHz accuracy. We obtain the following values for the energy levels: 12 985.169 60(13)(15) cm for the 4P1/2 state (D1 line); 13 042.875 95(14)(15) cm for the 4P3/2 st...

متن کامل

ar X iv : p hy si cs / 0 60 51 63 v 3 6 J ul 2 00 6 Frequency shift of hyperfine transitions due to blackbody radiation

We have performed calculations of the size of the frequency shift induced by a static electric field on the clock transition frequencies of the hyperfine splitting in Yb, Rb, Cs, Ba, and Hg. The calculations are used to find the frequency shifts due to blackbody radiation which are needed for accurate frequency measurements and improvements of the limits on variation of the fine structure const...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002