Fluorescent-based single-strand conformation polymorphism/heteroduplex capillary electrophoretic mutation analysis of the P53 gene.

نویسندگان

  • Chunxia Zhao
  • Guowang Xu
  • Xianzhe Shi
  • Jianmei Ma
  • Yan Zhang
  • Shen Lv
  • Qianfeng Weng
  • Qing Yang
چکیده

Fluorescent-based single-strand conformation polymorphism (F-SSCP) analysis with capillary electrophoresis (CE) is the most common method for the detection of mutation because of its high sensitivity and resolution. In this study, we prepared an inexpensive linear polyacrylamide (LPA), and successfully applied it to CE-SSCP analysis and tandem CE-SSCP/heteroduplex analysis (HA) of the P53 gene on an ABI capillary genetic analyzer. A comparison of the sieving capabilities of a homemade LPA and commercial polydimethylacrylamide (PDMA) demonstrates that the homemade LPA has a higher resolution, a shorter analysis time, and is more suitable for tandem SSCP/HA than commercial PDMA. To show the usefulness, mutations of P53 gene exon 7 - 8 in 37 tumor samples were investigated by using homemade LPA. The results indicate that 10 mutations were found in 9 of 37 cases; the majority of P53 mutations were missense mutations, and 70% were located in exon 7, which plays an important role in neoplastic progression in human tumorigenesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-throughput, high-sensitivity genetic mutation detection by tandem single-strand conformation polymorphism/heteroduplex analysis capillary array electrophoresis.

We present the first optimization of linear polyacrylamide (LPA)-based DNA separation matrixes for an automated tandem microchannel single-strand conformation polymorphism (SSCP)/heteroduplex analysis (HA) method, implemented in capillary arrays dynamically coated with poly(N-hydroxyethylacrylamide) (polyDuramide). An optimized protocol for sample preparation allowed both SSCP and HA species to...

متن کامل

High-throughput mutation detection method to scan BRCA1 and BRCA2 based on heteroduplex analysis by capillary array electrophoresis.

BACKGROUND Scanning for mutations in BRCA1 and BRCA2 in a large number of samples is hampered by the large sizes of these genes and the scattering of mutations throughout their coding sequences. Automated capillary electrophoresis has been shown to be a powerful system to detect mutations by either single-strand conformation polymorphism or heteroduplex analysis (HA). METHODS We investigated ...

متن کامل

Technical challenges in applying capillary electrophoresis-single strand conformation polymorphism for routine genetic analysis.

Recent and future advances in population genetics will have a significant impact on health care practices and the economics of health care provision only if a spectrum of patient-tailored, effective methods of DNA screening for sequence alterations has been developed. Genetic screening by capillary electrophoresis-single strand conformation polymorphism (CE-SSCP), which is based upon the differ...

متن کامل

تعیین جهش در اگزون 8 ژن p53 در بیماران مبتلا به تومور مغزی از نوع آستروسایتوما

Background: Most studies have shown that there are association between the development and malignancy of brain tumors and tumor suppressor genes and oncogenes. The aim of this project was to investigate the P53 gene mutations in exon 8 in patients with astrocytoma type’s brain tumor. Methods: In this present survey, The DNA isolation from 30 samples of brain tissue was done by phenol-c...

متن کامل

Mutation Detection by Single Strand Conformation Polymorphism and Heteroduplex Analysis

Single strand conformation polymorphism (SSCP) and heteroduplex analysis (HDA) are two of the most popular electrophoresis-based mutation detection methods. Coupled to DNA amplification of the sequence to be analyzed, these techniques have become the methods of choice for a number of molecular diagnostic laboratories. This can be explained mainly by the numerous advantages, namely their technic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 7  شماره 

صفحات  -

تاریخ انتشار 2004