Simultaneous Determination of Oxysterols, Cholesterol and 25-Hydroxy-Vitamin D3 in Human Plasma by LC-UV-MS

نویسندگان

  • Rohini Narayanaswamy
  • Vignesh Iyer
  • Prachi Khare
  • Mary Lou Bodziak
  • Darlene Badgett
  • Robert Zivadinov
  • Bianca Weinstock-Guttman
  • Todd C. Rideout
  • Murali Ramanathan
  • Richard W. Browne
چکیده

BACKGROUND Oxysterols are promising biomarkers of neurodegenerative diseases that are linked with cholesterol and vitamin D metabolism. There is an unmet need for methods capable of sensitive, and simultaneous quantitation of multiple oxysterols, vitamin D and cholesterol pathway biomarkers. METHODS A method for simultaneous determination of 5 major oxysterols, 25-hydroxy vitamin D3 and cholesterol in human plasma was developed. Total oxysterols were prepared by room temperature saponification followed by solid phase extraction from plasma spiked with deuterated internal standards. Oxysterols were resolved by reverse phase HPLC using a methanol/water/0.1% formic acid gradient. Oxysterols and 25-hydroxy vitamin D3 were detected with atmospheric pressure chemical ionization mass spectrometry in positive ion mode; in-series photodiode array detection at 204nm was used for cholesterol. Method validation studies were performed. Oxysterol levels in 220 plasma samples from healthy control subjects, multiple sclerosis and other neurological disorders patients were quantitated. RESULTS Our method quantitated 5 oxysterols, cholesterol and 25-hydroxy vitamin D3 from 200 μL plasma in 35 minutes. Recoveries were >85% for all analytes and internal standards. The limits of detection were 3-10 ng/mL for oxysterols and 25-hydroxy vitamin D3 and 1 μg/mL for simultaneous detection of cholesterol. Analytical imprecision was <10 %CV for 24(S)-, 25-, 27-, 7α-hydroxycholesterol (HC) and cholesterol and ≤15 % for 7-keto-cholesterol. Multiple Sclerosis and other neurological disorder patients had lower 27-hydroxycholesterol levels compared to controls whereas 7α-hydroxycholesterol was lower specifically in Multiple Sclerosis. CONCLUSION The method is suitable for measuring plasma oxysterols levels in human health and disease. Analysis of human plasma indicates that the oxysterol, bile acid precursors 7α-hydroxycholesterol and 27-hydroxycholesterol are lower in Multiple Sclerosis and may serve as potential biomarkers of disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid and simultaneous determination of 25-OH-vitamin D2 and D3 in human serum by LC/MS/MS: Validation and uncertainty assessment

25-OH Vitamin D3 and 25-OH Vitamin D2 were determined by rapid, simple and validated LC/MS/MS method without using SPE and isotopic standard. The relative standard deviations (RSD) were found to be 3.1 and 2.8 % for 25-OH Vitamin D3 and 25-OH Vitamin D2, respectively. The correlation coefficient was grater than 0.99 for both analytes in the calibration range. The recoveries at 100 μg L concentr...

متن کامل

Correlation Between Serum Vitamin D Level and the Severity of Atopic Dermatitis Associated With Food Sensitization

PURPOSE A growing body of literature has linked vitamin D deficiency with allergic diseases, particularly atopic dermatitis (AD). In this study, we investigated the association between serum vitamin D status and the clinical manifestation of AD. We also developed an analytical method for the simultaneous determination of 25-hydroxy vitamin D3 (25(OH)D3), using liquid chromatography (LC) coupled...

متن کامل

Cholesterol metabolites exported from human brain

The human brain contains approximately 25% of the body's cholesterol. The brain is separated from the circulation by the blood brain barrier. While cholesterol will not passes this barrier, oxygenated forms of cholesterol can cross the barrier. Here by measuring the difference in the oxysterol content of blood plasma in the jugular vein and in a forearm vein by mass spectrometry (MS) we were ab...

متن کامل

Accurate and reliable quantification of 25-hydroxy-vitamin D species by liquid chromatography high-resolution tandem mass spectrometry.

In general, mass spectrometric quantification of small molecules in routine laboratory testing utilizes liquid chromatography coupled to low mass resolution triple-quadrupole mass spectrometers (QQQs). Here we introduce high-resolution tandem mass spectrometry (quadrupole-Orbitrap) for the quantification of 25-hydroxy-vitamin D [25(OH)D], a marker of the vitamin D status, because the specificit...

متن کامل

Comparing the Amount of 25-Hydroxy Vitamin D3 Concentrated in Serum of Normal and Overweight/ Obese Women and Its Relation to Metabolic Syndrome

Background & Objective: The relationship between vitamin D3 and risk factors of metabolic syndrome is unclear. This study aimed to investigate the vitamin D3 kevel of women and its relation with metabolic syndrome risk factors. Materials & methods: A cross-sectional study conducted between 200 healthy women aged 20 to 50 in two groups of normal BMI (BMI=18.5-24.9 kg/m2) and overweight/obe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015