An EEG system with carbon wire electrodes and an anti-polarization circuit for simultaneous EEG-fMRI recording

نویسندگان

  • M. Negishi
  • I. Laufer
  • M. Abildgaard
  • T. Nixon
  • R. T. Constable
چکیده

Background Simultaneous EEG-fMRI (Electroencephalography-functional Magnetic Resonance Imaging) recording offers high temporal resolution electrophysiological recording and high spatial resolution hemodynamic recording from the same experimental runs. Carbon wire electrodes (but not solid electrodes with carbon leads) are suitable for simultaneous EEG-fMRI recording, especially in high field MRI, because they cause less RF (Radio Frequency) heating (Bonmassar, 2004) and less susceptibility artifacts (Krakow et al., 2000) than metallic electrodes. In addition, carbon wire electrodes are comfortable to wear during long recording sessions. However, carbon wire electrodes have not been used widely in human EEG because of its relatively high impedance and the electrode polarization, or imbalance of DC potentials among electrodes. The problem associated with the high impedance is negligible, especially with EEG recorders with high input impedances. Electrode polarization causes randomly fluctuating potentials and saturation of the EEG recorder. In this study, we developed a prototype EEG system with three carbon wire electrodes and a inhouse made pre-amplifier that was equipped with an anti-polarization mechanism. The system was evaluated in an auditory ERP (event-related potential) experiment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

“Eyes Open – Eyes Closed” EEG/fMRI data set including dedicated “Carbon Wire Loop” motion detection channels

This data set contains electroencephalography (EEG) data as well as simultaneous EEG with functional magnetic resonance imaging (EEG/fMRI) data. During EEG/fMRI, the EEG cap was outfitted with a hardware-based add-on consisting of carbon-wire loops (CWL). These yielded six extra׳CWL׳ signals related to Faraday induction of these loops in the main magnetic field "Measurement and reduction of mot...

متن کامل

Simultaneous EEG-CBV (Electroencephalography – Cerebral Blood Volume) measurements of epileptic spikes

Background: Simultaneous EEG and VASO (Vascular Space Occupancy) imaging can be used to characterize CBV (cerebral blood volume) changes during interictal epileptic discharges (IED’s). However, the VASO sequence causes more RF pulse artifacts in the EEG than spin-echo or gradient-echo functional MRI (fMRI) sequences, because the global inversion pulses in the VASO sequence require higher RF pow...

متن کامل

A method for removing imaging artifact from continuous EEG recorded during functional MRI.

Combined EEG/fMRI recording has been used to localize the generators of EEG events and to identify subject state in cognitive studies and is of increasing interest. However, the large EEG artifacts induced during fMRI have precluded simultaneous EEG and fMRI recording, restricting study design. Removing this artifact is difficult, as it normally exceeds EEG significantly and contains components...

متن کامل

O16: Long Term Video EEG (AC/DC) Monitoring

Long term video electro-encephalographic (EEG) monitoring (LTM) is defined as the continuous and synchronized recording of EEG and multimedia to analyze brain abnormalities. A conventional LTM system continuously records EEG in the frequency range of 0.5-70Hz. The data synchronization, the high-volume data management, the system reliability as well as noise reduction remain significant challeng...

متن کامل

Carbon-wire loop based artifact correction outperforms post-processing EEG/fMRI corrections—A validation of a real-time simultaneous EEG/fMRI correction method

Simultaneous EEG-fMRI combines two powerful neuroimaging techniques, but the EEG signal suffers from severe artifacts in the MRI environment that are difficult to remove. These are the MR scanning artifact and the blood-pulsation artifact--strategies to remove them are a topic of ongoing research. Additionally large, unsystematic artifacts are produced across the full frequency spectrum by the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007