Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo®-derived cardiac output measurements: a prospective comparison study

نویسندگان

  • Savvas Eleftheriadis
  • Zisis Galatoudis
  • Vasilios Didilis
  • Ioannis Bougioukas
  • Julika Schön
  • Hermann Heinze
  • Klaus-Ulrich Berger
  • Matthias Heringlake
چکیده

INTRODUCTION The reliability of autocalibrated pressure waveform analysis by the FloTrac-Vigileo(R) (FTV) system for the determination of cardiac output in comparison with intermittent pulmonary arterial thermodilution (IPATD) is controversial. The present prospective comparison study was designed to determine the effects of variations in arterial blood pressure on the reliability of the FTV system in patients undergoing coronary artery bypass grafting (CABG). METHODS Comparative measurements of cardiac output by FTV (derived from a femoral arterial line; software version 1.14) and IPATD were performed in 16 patients undergoing elective CABG in the period before institution of cardiopulmonary bypass. Measurements were performed after induction of anesthesia, after sternotomy, and during five time points during graft preparation. During graft preparation, arterial blood pressure was increased stepwise in intervals of 10 to 15 minutes by infusion of noradrenaline and lowered thereafter to baseline levels. RESULTS Mean arterial blood pressure was varied between 85 mmHg and 115 mmHg. IPATD cardiac output did not show significant changes during periods with increased arterial pressure either during sternotomy or after pharmacological manipulation. In contrast, FTV cardiac output paralleled changes in arterial blood pressure; i.e. increased significantly if blood pressure was raised and decreased upon return to baseline levels. Mean arterial blood pressure (MAP) and FTV cardiac output were closely correlated (r = 0.63 (95% confidence interval [CI]: 0.49 - 0.74), P < 0.0001) while no correlation between MAP and IPATD cardiac output was observed. Bland-Altman analyses for FTV versus IPATD cardiac output measurements revealed a bias of 0.4 l/min (8.5%) and limits of agreement from 2.1 to -1.3 l/min (42.2 to -25.3%). CONCLUSIONS Acute variations in arterial blood pressure alter the reliability of the FlowTrac/Vigileo device with the second-generation software. This finding may help to explain the variable results of studies comparing the FTV system with other cardiac output monitoring techniques, questions the usefulness of this device for hemodynamic monitoring of patients undergoing rapid changes in arterial blood pressure, and should be kept in mind when using vasopressors during FTV-guided hemodynamic optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is supra-ventricular arrhythmia a reason for the bad performance of the FlowTrac device?

In their recent paper evaluating arterial waveform analysis as a tool to measure cardiac output (CO), Michael Sander and colleagues do not provide data on the heart rhythms of their cardiac surgery patients [1]. As the FloTrac (Flowtrac/Vigileo, Edwards Lifescience, Munich, Germany) device calculates CO from an arterial pressure-based algorithm, integrating vessel compliance and peripheral resi...

متن کامل

ثبات همودینامیک با کدام رژیم هوشبری در جراحی پیوند رگ‌های کرونر قلب بیماران تحت درمان با بتا-بلوکر بیشتراست؟سوفنتانیل سیس - آتراکوریوم یا سوفنتانیل-پانکرونیوم

    Background and Aim: Hemodynamic stability during anesthesia and operation is the most important aim of anesthesiologists. Every anesthetic drug has its own hemodynamic effects. The interaction of these drugs with each other and with preoperative drugs of the patients, may cause critical changes in patient's hemodynamic status. For a perfect anesthesia induction, while using high doses of op...

متن کامل

Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis.

BACKGROUND Recently, continuous monitoring of cardiac output (CO) based on pulse contour analysis (Vigileo) has been introduced into practice. In this clinical study, we evaluated the accuracy of this system by comparing it with the transpulmonary thermodilution technique (TPID) in septic patients. METHODS We studied 24 mechanically ventilated patients with septic shock (16 male, 8 female, ag...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...