Identification of Metabolites of 6'-Hydroxy-3,4,5,2',4'-pentamethoxychalcone in Rats by a Combination of Ultra-High-Performance Liquid Chromatography with Linear Ion Trap-Orbitrap Mass Spectrometry Based on Multiple Data Processing Techniques.

نویسندگان

  • Siyi Liu
  • Yanyun Che
  • Fei Wang
  • Zhanpeng Shang
  • Jianqiu Lu
  • Shengyun Dai
  • Jiayu Zhang
  • Wei Cai
چکیده

In this study, an efficient strategy was established using ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap mass spectrometry (UHPLC-LTQ-Orbitrap MS) to profile the in vivo metabolic fate of 6'-hydroxy-3,4,5,2',4'-pentamethoxychalcone (PTC) in rat urine and feces. The UHPLC-LTQ-Orbitrap method combines the high trapping capacity and MS(n) scanning function of the linear ion trap along with accurate mass measurements within 5 ppm and a resolving power of up to 30,000 over a wider dynamic range compared to many other mass spectrometers. In order to reduce the potential interferences of endogenous substances, the post-acquisition processing method including high-resolution extracted ion chromatogram (HREIC) and multiple mass defect filters (MMDF) were developed for metabolite detection. As a result, a total of 60 and 35 metabolites were detected in the urine and feces, respectively. The corresponding in vivo reactions such as methylation, hydroxylation, hydrogenation, decarbonylation, demethylation, dehydration, methylation, demethoxylation, sulfate conjugation, glucuronide conjugation, and their composite reactions were all detected in this study. The result on PTC metabolites significantly expanded the understanding of its pharmacological effects, and could be targets for future studies on the important chemical constituents from herbal medicines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Profiling and Identification of the Metabolites of Evodiamine in Rats using Ultra–Performance Liquid Chromatography with Linear Ion Trap Orbitrap Mass Spectrometer

Purpose: To develop a highly sensitive and specific ultra-performance liquid chromatography with linear ion trap Orbitrap mass spectrometer (UPLC-LTQ-Orbitrap) method to profile and identify the metabolites of evodiamine in rats. Methods: First, blood samples were collected after oral administration of evodiamine to rats (50 mg/kg). Next, the plasma samples were pretreated using a solid-phase e...

متن کامل

Systematic Analysis of Absorbed Anti-Inflammatory Constituents and Metabolites of Sarcandra glabra in Rat Plasma Using Ultra-High-Pressure Liquid Chromatography Coupled with Linear Trap Quadrupole Orbitrap Mass Spectrometry.

Ultra-high-pressure liquid chromatography (UHPLC) was coupled with linear ion trap quadrupole Orbitrap mass spectrometry (LTQ-Orbitrap) and was used for the first time to systematically analyze the absorbed components and metabolites in rat plasma after oral administration of the water extract of Sarcandra glabra. This extract is a well-known Chinese herbal medicine for the treatment of inflamm...

متن کامل

Rapid Characterization and Identification of Flavonoids in Radix Astragali by Ultra-High-Pressure Liquid Chromatography Coupled with Linear Ion Trap-Orbitrap Mass Spectrometry.

A simple and effective method was established for separation and characterization of flavonoid constituents in Radix Astragali (RA) by combination of ultra-high-pressure liquid chromatography with LTQ-Orbitrap tandem mass spectrometry (u-HPLC-LTQ-Orbitrap-MS(n)). For three major structural types of flavonoids, the proposed fragmentation pathways and major diagnostic fragment ions of isoflavones...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Molecules

دوره 21 10  شماره 

صفحات  -

تاریخ انتشار 2016