Nonlinear Damping Identification in Precast Prestressed Reinforced Concrete Beams
نویسندگان
چکیده
This article presents a damage detection method for prestressed reinforced concrete (PRC) elements based on free vibration tests and nonlinear damping identification. Integrated static and dynamic experiments were carried out on three precast PRC beam specimens. The static loading induced different levels of damage to the beams. At each damage level, impulsive loading was applied to the beams and the free vibration response was measured. The dynamic response data were processed using different methods including the multi-input multi-output (MIMO) curve fitting and the Hilbert transform techniques. A strong correlation is observed between the level of concrete damage (cracks) and the amount of nonlinear energy dissipation that can be modeled by means of quadratic damping. The nonlinear damping can be extracted from the free vibration response for each vibration mode. The proposed method is suited for quality control when manufacturing precast PRC members, and can be further extended for in situ detection of damage in concrete structures under ambient vibration. ∗To whom correspondence should be addressed. E-mail: [email protected].
منابع مشابه
Seismic Retrofitting RC Structures with Precast Prestressed Concrete Braces- ABAQUS FEA Modeling
Precast prestreesed concrete braces are a new method for seismic strength of Concrete Structures which has the following benefits: a) no wet concrete work in construction site b) No bolt or anchorage to the existing frame c) easy to apply d) short construction period e) low construction cost, to evaluate seismic performance of strengthened structure a model consist of existing frame and concret...
متن کاملResearch Record, RR-102
Since the 1950’s, prestressed concrete beams have become a factor in almost one third of all new bridge construction in the United States. In Michigan, prestressed concrete was introduced in 1954 and the first prestressed concrete side-by-side box-beam bridge was built in 1955. Pontis data indicates 2,054 side-by-side prestressed concrete box-beam bridges in Michigan; 236 are part of the Nation...
متن کاملModeling of L-Shaped, Precast, Prestressed Concrete Spandrels
PCI JOURNAL This paper presents the results of nonlinear fi nite element analyses conducted to model the behavior of L-shaped, precast, prestressed concrete spandrels constructed with open web reinforcement. The fi nite element model was calibrated using experimental results from recent tests of slender, L-shaped, precast, prestressed concrete spandrels. Detailed correlative studies between ana...
متن کاملCOMPARATIVE COSTS OF THE PRODUCTION, TRANSPORT AND ASSEMBLY STAGES OF PRESTRESSED PRECAST SLABS USING GENETIC ALGORITHMS
In the precast structures, optimization of structural elements is of great interest mainly due to a more rationalized way that elements are produced. There are several elements of precast prestressed concrete that are objects of study in optimization processes, as the prestressed joist applied in buildings slabs. This article inquires into cost minimization of continuous and simply supported sl...
متن کاملPrecast Piles for Route 40 Bridge in Virginia Using Concrete Filled FRP Tubes
and findings of laboratory and field tests of a new generation of precast composite piles used for the first time in the construction of the Route 40 highway bridge over the Nottoway River in Virginia. The piles consisted of 24.6 in. (625 mm) diameter concrete-filled glass fiber reinforced polymer (GFRP) circular tubes, with a 0.21 in. (5.3 mm) wall thickness. The composite piles extended above...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Comp.-Aided Civil and Infrastruct. Engineering
دوره 24 شماره
صفحات -
تاریخ انتشار 2009